15) Has the end user been given the name and telephone number of an authorized service
agent?
16) Has the warranty card been filled out and forwarded to the factory for warranty
registration?
I. Startup
All parts are factory-adjusted. Improper adjustments may adversely affect safety,
performance, component life, and warranty coverage.
• If the unit is turned off, wait for at least 3 minutes before restarting the unit to
prevent damage to the compressor.
• To prevent damage to the water pump seal, do not leave the control switch in the
"SERVICE" position when the water tank is empty.
• At startup, confirm that all internal and external connections are free of leaks.
• The remote condensing unit must have power for a minimum of 4 hours prior to
startup to prevent compressor damage.
1) If removed, replace the splash curtain, front frame, and all panels except the front panel
in their correct positions. See Fig. 20. If not already removed, remove the front panel.
2) Open the water supply line shut-off valve.
3) Move the control switch to the "ICE" position, then replace the front panel in its correct
position.
4) Turn on the power supply. During the first 5 minutes of the freeze cycle, confirm bin
control operation by pressing and holding the bin control's actuator paddle until the
icemaker shuts down. The icemaker should shut down in approximately 15 seconds.
5) After confirming bin control operation, release the bin control's actuator paddle and
allow the icemaker to resume operation.
6) After 10 minutes of operation, remove the front panel and move the control switch to the
"OFF" position. Turn off the power supply.
7) Remove the insulation panel, front frame, and splash curtain.
8) Drain the water tank by disconnecting the pump suction hose at the evaporator case
wall.
9) Disconnect the drain pipe and float connection hose at the evaporator case wall.
Disconnect the water tank drain hose from the bottom of the water tank.
10) Remove the water tank.
11) Clean the dispenser unit/storage bin liner and water tank using a neutral cleaner. Rinse
thoroughly after cleaning.
12) Replace the water tank in the icemaker, then reconnect the hoses and drain pipe.
WARNING