Icemaker - Hoshizaki KM-1601SAH Instruction Manual

Stackable crescent cuber
Hide thumbs Also See for KM-1601SAH:
Table of Contents

Advertisement

1. Icemaker

• Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" nominal
ID copper water tubing or equivalent is required for the icemaker water supply line.
• An icemaker water supply line shut-off valve and drain valve should be installed.
• Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" nominal ID hard pipe or equivalent
is required for the icemaker drain line. Condensation drain outlet is 3/8" OD hard tube.
The condensation drain line can be connected to the icemaker drain line or can be run
separately.
Remote Condenser
Line Set Connections
Icemaker
Drain Outlet
3/4" FPT
Bin Drain Outlet
3/4" FPT
Fig. 17
Icemaker Water
Supply Inlet
1/2" FPT
Icemaker
Bin
Vent Tube
Minimum 3/4"
Nominal ID Hard Pipe
KM-1601SAH/3
KM-1601SRH/3
Vent Tube
Icemaker Water Supply
Line Drain Valve
Condensation
Drain Outlet
3/8" OD Hard Tube
Separate piping to approved drain.
Leave a 2-inch (5-cm) vertical air
gap between the end of each pipe
and the drain.
2-inch (5-cm) air gap
29
Minimum 3/8" Nominal ID
Copper Water Tubing
Icemaker Water Supply
Line Shut-Off Valve
Floor Drain

Hide quick links: