APPLICATION
The V4043H valve has been designed to control the flow of
water in iron and copper pipe systems. Although specifically
designed for small bore domestic central heating systems, the
valve can be used in commercial and industrial applications.

SPECIFICATIONS

Voltage: 230-240V ~ 50 Hz
Power Consumption: 6W
Lead Supplied: 1 metre, 5 core
Operating Temperature Range: +5 to +88° C
Maximum Ambient Temperature: +52° C
Pipe Fitting Sizes: 22 mm & 28 mm compression fitting, 3/4"
& 1" BSP
Dimensions and KV values: See diagrams
SPARES AVAILABLE
Powerhead
Part No. 40003916-001
Motor
Part No. 40002737-003
Ball & O-Ring Kit
Part No. 272742A CARD
A
CLEARANCE
FOR COVER
B
REMOVAL
1/2D
1/2D
D
Fig. 1. Dimensions
A
87
C
B
98
C
60
1/2 IN.
94
22MM
112
D
1 IN.
92
117
28MM

INSTALLATION INSTRUCTIONS

Fig. 2. Flow Characteristics
Put Bar Code Here
95C-10819—04

Advertisement

loading

Summary of Contents for Honeywell V4043H

  • Page 1: Installation Instructions

    V4043H Motorised Zone Valve INSTALLATION INSTRUCTIONS APPLICATION The V4043H valve has been designed to control the flow of water in iron and copper pipe systems. Although specifically designed for small bore domestic central heating systems, the valve can be used in commercial and industrial applications.
  • Page 2 V4043H MOTORISED ZONE VALVE INSTALLATION PLUMBING V4043H incorporates a manual lever, the lever should The valve may be plumbed in at any angle, but must not be normally be in ‘AUTO’ position, but can be moved to ‘MAN. mounted so that the valve head is below the horizontal level of OPEN’...
  • Page 3 WIRING The wiring diagram below shows relevant connections to a NOTES: Honeywell junction box (Part No. 42002116-001). Ensure that a. Wiring diagram shows connections to a programmer each numbered, lettered or coloured wire is connected to the with separate control of heating and hot water.
  • Page 4 3. Confirm correct heating functions as follows: Whilst Honeywell takes all practicable steps to design and manufacture its products to comply with the requirements of the Heath and Safety at Work Act 1974, all products must be properly used and Purchasers are reminded that their obligations under the Act are to ensure that the installation and operation of such products at a place of work should be safe and without risk to them.