Operation

Base Operation
Remote controller
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode
changes as follows:
Remote controller:
AUTO
COOL
3.Select temp.setting
Press
/
Every time the button is pressed, temp.setting
o
increase 1
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
C,if kept depressed, it will
o
decrease rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed
changes as
follows:
Remote controller:
LOW
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
Remote
Operation
Controller
Mode
AUTO
COOL
DRY
FAN
HEAT
4
1
2
DRY
FAN
HEAT
button
AUTO
MED
HI
Note
Under the mode of auto operation, air conditioner
will automatically select Cool or Heat operation
according to room temperature. When FAN is set
to AUTO, the air conditioner automatically adjusts
the fan speed according to room
temperature.
In DRY mode, when room temperature becomes
lower than temp.setting+2
C, unit will run
o
intermittently at LOW speed regardless of FAN
setting.
In FAN operation mode , the unit will not operate in
COOL or HEAT mode but only in FAN mode ,
AUTO is not available in FAN mode. And temp.
setting is disabled. In FAN mode, sleep operation
is not available.
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller
is defective or lost.
When the emergency operation switch is
pressed,the" Pi "sound is heard once, which
means
the start of this operation.
In this operation, the system automatically selects
the operation modes,cooling or fan or heat,
according to the room temperature.
.
Room
Operation
temperature
mode
ABOVE 24
C
O
COOLING
HEAT
BELOW 24
C
O
ooling only uint)
Operation
(C
Room temperature
O
BELOW 24
C
It is not possible to operate in dry mode.
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room
temperature is below 16
normal operation.
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice,
your finger from the switch: the cooling
operation starts with the air flow speed "Hi".

Air Flow Direction Adjustment

1.Status display of air flow
Vertical flap
Pos.1
Pos.2
Pos.4
Pos.5
2.Left and right air flow adjustment
For each press of
displays as follows :
remote controller:
Pos.1
Pos.2
Pos.5
Pos.6
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
at air outlet if all vertical louvers are
right.
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
otherwise, condensate water might occur.
Note:
When restart after remote turning off, the remote
controller will automatically
set swing position.
3
Timer
Designated
Air flow
mode
temperature
AUTOMATIC
NO
24
C
O
AUTOMATIC
NO
24
C
O
Designated
Timer
mode
temperature
mode
O
FAN
NO
24
C
o
C, do not use it in the
release
Pos.3
Pos.6
(Auto swing)
button, remote controller
Pos.3
Pos.4
Pos.7
Pos.8
adjusted to left or
mode ,
memorize the previous
emergency
operation
switch
Air flow
AUTOMATIC
test operation
switch