Heat & Glo FB-Grand Installer's Manual page 20

Hide thumbs Also See for FB-Grand:
Table of Contents

Advertisement

FEED PLUG
THROUGH HOLE
JUNCTION
BOX
SCREW
Figure 9.
PROVIDED
Junction box installation
Optional Accessories
Installation of the electrical junction box is required if using
a blower or remote. To install:
• Uncoil the junction box cord and feed the end of the
cord through the hole on the right side of the base pan.
• Turn the junction box at a 45-degree angle and insert it
into the sidewall of the base pan.
• Turn junction box so it is flush with sidewall and screw
into place with the screw provided in the manual bag.
• Gently pull the end of the cord until cord is tight. Place
the strain relief on the cord and then place it into hole on
base pan.
• Plug the cord into a convenient outlet. An electrician
may install an outlet box inside the fireplace. Place the
outlet in the lower, back corner of the fireplace supplied.
Make sure fan doesn't touch back wall.
BLK
BLK
BLK
TEMPERATURE
SENSOR SWITCH
NOTE: IF ANY OF THE ORIGINAL WIRE AS SUP-
PLIED WITH THE APPLIANCE MUST BE RE-
PLACED, IT MUST BE REPLACED WITH TYPE
105
0
C RATED WIRE.
Figure 10. Fan Wiring Diagram
INSERT STRAIN RELIEF
AROUND CORD IN THIS END
FROM OUTSIDE OF UNIT
SIDEWALL
VARIABLE SPEED CONTROL
JUNCTION BOX
BLK
BLK
BLK
BLK
GROUND
BLK
110-120 VAC
WARNING: MUST USE THE CORD SUPPLIED
!
WITH THE J-BOX.
Fan Option (FB-IN & FB-Grand ONLY)
On units already installed removal of decorative front, sur-
round and gas insert is required.
• Detach flexible liner from back of unit.
• Remove the four screws on the coverplate (see Figure 11).
• Bend up the tabs on the base pan (see Figure 10).
• Place the blower in between the bend up tabs.
• Install and wire the blower per instruction shipped with
the fan.
• The ground wire of the fan can clip on the side of the
base pan.
Reinstall the cover plate back on the unit. Make sure
the fan does not make contact with the back wall.
Figure 11.
BLK
WHT
WHT
GRN
WHT
FAN
GROUND WIRE
(ATTACH TO ANY
METAL SURFACE)
20
COVER
FAN
GROUND
WIRE
BLOWER RECEPTACLE
BLOWER
JUNCTION
BOX
TEMPERATURE
SENSOR SWITCH
SPEED CONTROL
(RHEOSTAT)
PLATE

Advertisement