Maintenance Tasks-Qualifi Ed Service Technician - Heat & Glo ST-36TR-IPI Owner's Manual

Hide thumbs Also See for ST-36TR-IPI:
Table of Contents

Advertisement

Ember Light Replacement
Frequency: As Required
By: Homeowner or Qualifi ed Service Technician
Tools needed: Protective gloves, 5/16 in. nut driver
In the lower gas valve compartment you will fi nd three ac-
cess panels for the three light bulbs. See Figure 3.1
Figure 3.1 Access Panel
1. Unplug the electrical cord as shown Figure 13.1.
2. Remove the two bolts using a 5/16 in. nut driver. See
Figure 3.2.
Figure 3.2 Remove Bolts
3. Pull the access panel to expose the light bulb. Wear-
ing clean cotton gloves, replace the bulb. Any skin
oils which get on a new bulb will greatly reduce the life
of the bulb. The bulb can be cleaned with isopropyl
alcohol. See Figure 3.3.
Figure 3.3 Replace Bulb
14
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13
B. Maintenance Tasks-Qualifi ed Service
Technician
The following tasks must be performed by a qualifi ed ser-
vice technician.
Gasket Seal and Glass Assembly Inspection
Frequency: Annually
By: Qualifi ed Service Technician
Tools needed: Protective gloves, drop cloth and a stable
work surface.
• Inspect gasket seal and its condition.
• Inspect fi xed glass assembly for scratches and nicks that
can lead to breakage when exposed to heat.
• Confi rm there is no damage to glass or glass frame.
Replace as necessary.
• Verify that fi xed glass assembly is properly retained and
attachment components are intact and not damaged.
Replace as necessary.
Logs
Frequency: Annually
By: Qualifi ed Service Technician
Tools needed: Protective gloves.
• Inspect for damaged or missing logs. Replace as necessary.
Refer to Section 14 for log placement instructions.
• Verify correct log placement and no fl ame impingement
causing sooting. Correct as necessary.
Firebox
Frequency: Annually
By: Qualifi ed Service Technician
Tools needed: Protective gloves, sandpaper, steel wool,
cloths, mineral spirits, primer and touch-up paint.
• Inspect for paint condition, warped surfaces, corrosion
or perforation. Sand and repaint as necessary.
• Replace fi replace if fi rebox has been perforated.
Control Compartment and Firebox Top
Frequency: Annually
By: Qualifi ed Service Technician
Tools needed: Protective gloves, vacuum cleaner, dust
cloths
• Vacuum and wipe out dust, cobwebs, debris or pet hair.
Use caution when cleaning these areas. Screw tips that
have penetrated the sheet metal are sharp and should
be avoided.
• Remove all foreign objects.
• Verify unobstructed air circulation.