Heat & Glo ST-36TR-IPI Owner's Manual
Heat & Glo ST-36TR-IPI Owner's Manual

Heat & Glo ST-36TR-IPI Owner's Manual

Hide thumbs Also See for ST-36TR-IPI:
Table of Contents

Advertisement

Models:
ST-36TR-IPI
ST-36TRLP-IPI
PIER-36TR-IPI
PIER-36TRLP-IPI
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13
Owner's Manual
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
Installation and Operation
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ST-36TR-IPI and is the answer not in the manual?

Questions and answers

Summary of Contents for Heat & Glo ST-36TR-IPI

  • Page 1 Technologies suggests NFI certifi ed or factory trained This appliance is only for use with the type(s) of gas indicated professionals, or technicians supervised by an NFI on the rating plate. certifi ed professional. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 2: Congratulations

    00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX XXXXXXXX XXXXXXXX (Serie): (Serie): Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 3: Table Of Contents

    J. Wall Switch Button Operation ..... . 55 Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 4 D. Contact Information ......86  = Contains updated information. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 5: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645F 02-18-13 Page 1 of 2 Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 6 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645F 02-18-13 Page 2 of 2 Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 7: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compli- ance with the applicable electrical codes, when it is in- stalled in locations such as in bathrooms or near sinks. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 9: User Guide

    • Install a switch lock or a wall/remote control with child protection lockout feature. DECORATIVE DOORS (NOT SHOWN) SECTION 2.E. FIXED GLASS ASSEMBLY SECTION 14.G. MANTEL SECTION 5.D HEARTH CLEAR SPACE SECTION 2.D. Figure 2.1 General Operating Parts Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 10: Blower Kit (Optional)

    WARNING! Risk of Fire or Asphyxiation! DO NOT op- erate fi replace with fi xed glass assembly removed. Figure 2.3 Clear Space Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 11: Lighting Instructions (Ipi)

    See installation and operating instructions accompanying appliance. For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 12: After Fireplace Is Lit

    Noise is caused by metal expanding and contracting as it heats up and cools down, similar to Metallic noise the sound produced by a furnace or heating duct. This noise does not affect the operation or longevity of the fi replace. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 13: Maintenance And Service

    • Carefully set fi xed glass assembly in place on fi replace. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 14: Maintenance Tasks-Qualifi Ed Service Technician

    Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided. • Remove all foreign objects. • Verify unobstructed air circulation. Figure 3.3 Replace Bulb Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 15 • Verify that there is not a short in fl ame sense circuit by checking continuity between pilot hood and fl ame- sensing rod. Replace pilot as necessary. Figure 3.4 IPI Pilot Flame Patterns Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 16: Installer Guide

    HEARTH EXTENSION Note: Dual venting configurations ARE NOT allowed. Appliance MUST be vented EITHER vertically OR horizontally. SURROUND MANTEL AND MANTEL LEG (SECTION 5.D) Figure 4.1 Typical System Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 17: Design And Installation Considerations

    Flat blade screwdriver 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulk (minimum of 300ºF continuous exposure rating) One 1/4 in. female connection (for optional fan). Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 18: Framing And Clearances

    36 in. 36 in. 914 mm 914 mm PIER 36 in. 914 mm 36 in. 914 mm 36 in. 914 mm Figure 5.1 Appliance Locations Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 19: Constructing The Appliance Chase

    Opening Opening (Height) (Width) (Width) (Width) (Depth) Inches 38-1/8 29-1/2 Millimeters 1092 * Adjust framing dimensions for interior sheathing (such as sheetrock) Figure 5.2 Clearances to Combustibles ST-36TR-IPI Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 20 Opening (Height) (Width) (Width) (Width) (Depth) Inches 8-5/8 38-1/8 31-5/8 Millimeters 1046 * Adjust framing dimensions for interior sheathing (such as sheetrock) Figure 5.3 Clearances to Combustibles PIER-36TR-IPI Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 21: Mantel And Wall Projections

    TOP EDGE OF THE OPENING Figure 5.8 Minimum Vertical and Maximum Horizontal Dimensions of Non-Combustibles MEASUREMENTS FROM TOP EDGE OF THE OPENING Figure 5.6 Minimum Vertical and Maximum Horizontal Dimensions of Combustibles Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 22 Note: Clearance from opening to perpendicular wall. Figure 5.9 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) SHEETROCK 3.5 in. AIR SPACE REQUIRED Figure 5.10 Non-Combustible Zone Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 23: Termination Locations

    Over 16/12 to 18/12 ..........7.0 Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 24 2 sides beneath the fl oor. venting system does not meet these requirements. • Vinyl protection kits are suggested for use with vinyl siding. Figure 6.3 Minimum Clearances for Termination Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 25: Continue Adding Vent Components

    (2) sheet metal screws. C. Install Support Brackets Refer to cinch pipe and termination cap installation in- structions. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 26: Vent Information And Diagrams

    DVP6 DVP12 Effective Height/Length DVP24 DVP36 DVP48 1219 DVP6A 3 to 6 76 to 152 DVP12A 3 to 12 76 to 305 Figure 7.2 DVP Pipe Effective Length Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 27: Vent Diagrams

    Installation requirements to replace the fi rst 90° elbow with two 45° elbows: elbow on rear vent appliances. 4 ft min. (1.22 m) 16 ft max. (4.87 m) Figure 7.3 Minimum Installation Requirements for Two 45° Elbows-Top Vent-Horizontal Termination Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 28 15 ft. 4.6 m 6 ft. 1.8 m 18 ft. 5.5 m = 50 ft. (15.2 m) Maximum = 18 ft. (5.5 m) Maximum INSTALLED HORIZONTALLY Figure 7.5 Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 29 3.7 m 3 ft. 914 mm 12 ft.* 3.7 m 6 ft 1.8 m = 18 ft. (5.5 m) Maximum = 50 ft. (15.2 m) Maximum Figure 7.6 Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 30 15-60 feet, an exhaust restrictor may baffle and refractory panel after exhaust be needed. The exhaust restrictor can be located in the restrictor installation. appliance manual bag. Figure 7.8 Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 31 MUST subtract one number from the table above. Example: Top vent 40 ft vertical with DVP pipe = 5-4 Top vent 40 ft vertical with SLP pipe = 4-3 Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 32 18 ft. 5.5 m = 18 ft (5.5 m) Maximum *No specifi c restrictions on this value EXCEPT cannot exceed 50 ft (15.2 m) INSTALLED HORIZONTALLY Figure 7.12 Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 33 = 16 in. (406 mm) Maximum No Elbow Figure 7.13 One 45° Elbow DO NOT use a 45º elbow in corner installations. Use two 90º elbow instead. Figure 7.14 Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 34 2.7 m 12 ft. 3.7 m INSTALLED = 40 ft (12.2 m) Maximum = 3 ft (94 mm) Maximum HORIZONTALLY = 12 ft (3.7 m) Maximum Figure 7.16 Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 35 1.5 m 10 ft. 6 ft. 1.8 m 12 ft. 3.7 m = 50 ft (15.2 m) Maximum = 16 ft (4.9 m) Maximum INSTALLED HORIZONTALLY Figure 7.18 Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 36 6 ft. 1.8 m *No specifi c restrictions on this value EXCEPT cannot exceed 50 ft. (15.2 m) Maximum = 6 ft. (1.8 m) Maximum INSTALLED Figure 7.20 HORIZONTALLY Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 37: Vent Clearances And Framing

    Figure 8.2 Wall Penetration Note: When venting off the top of the unit and terminating horizontally, using SLP pipe, a 10 in. x 10 in. framing hole is required. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 38: Vertical Penetration Framing

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 39: Install Attic Insulation Shield

    • Bend all tabs inward 90° around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 40: Appliance Preparation

    Note: The vent gasket can found in the manual bag. Figure 9.2 Cut the metal retaining band and fold the sides Proceed to Section 9. C. out. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 41: Rear Vent

    Secure the vent gasket to the appliance with two self-tapping screws found in the manual bag. Note: The vent gasket can found in the manual bag. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 42: Securing And Leveling The Appliance

    90º Note: Once appliance is setup for top or rear venting, it CANNOT be changed at a later time. Figure 9.9 Proper Positioning and Leveling of an Appliance Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 43: Installing Vent Pipe (Dvp And Slp Pipe)

    fl ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 44: Assemble Vent Sections (Slp Pipe Only)

    • Only outer pipes are sealed, sealing the inner fl ue is not Figure 10.5 Adding Venting Components required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 45: Secure The Vent Sections

    Figure 10.10 Rotate Seams for Disassembly connection point to appliance. 120º Figure 10.11 Align and Disassemble Vent Sections Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 46: Install Decorative Ceiling Components (Slp Only)

    fl aps and the roof. WARNING! Risk of Fire! Clean out ALL materials from Figure 10.13 inside the support box and complete the vertical vent run and termination. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 47: Install Metal Roof Flashing

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.15. Figure 10.17 Assembling the Storm Collar Around the Pipe Figure 10.17 Assembling the Storm Collar Around the Pipe Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 48: Install Vertical Termination Cap

    • Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 10.19. Figure 10.19 Wall Thimble Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 49: Install Horizontal Termination Cap (Dvp And Slp Pipe)

    DVP-TRAP1 can adjust 1-1/2 in. (3-1/8 to 4-5/8 in.) DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 50: Gas Information

    fl exible gas connector are connected to the 1/2 inch consult local gas utility. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 51: Electrical Information

    Verify proper operation after servicing. WARNING! Risk of Shock! Replace damaged wire with type 105° C rated wire. Wire must have high temperature insulation. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 52: Wsk-Mlt Multifunction Wall Switch

    Na- tional Electric Code ANSI/NFGA No. 70- current (in the United States), or with the current CSA C22.1 CANADI- AN ELECTRIC CODE (in Canada). Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 53 BLACK FAN THERMOSTAT FAN CORD EMBER LIGHT GROUND PIGTAIL CONNECTION CONNECTOR BLOCK GREEN BLACK BLACK SEE DETAIL IN FIGURE 12.3 CONNECTION Figure 12.2 Intellifi re (IPI) Wiring Diagram Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 54: Install The Flame Solenoid

    GAS CONTROL VALVE KNOB SCREW WASHER VARIABLE REGULATOR WASHER VARIABLE REGULATOR SOLENOID FLAME CONTROL VARIABLE JAM NUT PLUNGER SOLENOID REGULATOR Figure 12.4 Install the Flame Solenoid Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 55: Wsk-Mlt Operating Instructions

    Fahrenheit and Centigrade Temperature Display. Automatic Operation: Controller will monitor temperature and control unit according to the set point. Manual Operation: Controller will not automatically change settings. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 56 This allows the pilot fl ame to stay lit when activated. A benefi t of this is reduced condensation on the glass at start-up in colder climate conditions. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 57: Finishing

    Figure 13.2 Folding Top Flap Step 3. Crease fl aps on left and right sides of splatter guard using the scored line as the guide. See Figure 13.2. Figure 13.5 Top slot Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 58 Pull outward gently, but fi rmly, Figure 13.8 Opening Lower Access Panel taking care not to tear or remove the inserted tabs. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 59: Mantel And Wall Projections

    TOP EDGE OF THE OPENING Figure 13.15 Minimum Vertical and Maximum Horizontal Dimensions of Non-Combustibles MEASUREMENTS FROM TOP EDGE OF THE OPENING Figure 13.13 Minimum Vertical and Maximum Horizontal Dimensions of Combustibles Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 60: Facing Material

    - Top and Sides 0 in. 0 in. 0 in. High Temperature Sealant (300° F/149° C min.) Top and Side Seal Joint Figure 13.17 Noncombustible Facing Diagram Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 61: Finishing Material

    Finishing materials 1 inch maximum thick. Finishing material between 1 and 2 inches thick. Stop fi nishing material fl ush with opening. Figure 13.21 Operable Hinge Door Figure 13.19 Overlap Fit Door Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 62 FINISHING MATERIAL 33-5/8 in. 37-1/4 in. Figure 13.22 Pier Door Finishing Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 63: Elevated Hearth Systems

    Note 1. Add dimensions to Exterior Wall Hole (Figure 8.2) and Rough Opening Height (Figure 5.2). Note 2. Verify Marble Cut Lengths on site prior to cutting. Note 3. Dimensions assume use of a 3/4 in. Hearth Pad. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 64: Appliance Setup

    Figure 14.1 Teco-Sil Start by applying the glass ember rock (Teco-Sil) to the base pan as shown in Figure 14.2. Figure 14.5 Painting Teco-Sil Figure 14.2 Teco-Sil Placement Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 65 • Save the remaining ember materials for use during Figure 14.6 Painting Teco-Sil appliance servicing. The embers provided should be enough for 3 to 5 applications. Figure 14.7 Placement of Embers Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 66: Install The Log Assembly

    LOG #2 (SRV2005-700): Position log #2 on the left grate bar and the pilot assembly. Use the cut out notches on the log to position it as shown. 2005-937F 9/08 Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 67 LOG #5 (SRV2005-704): Using the sharp notch on the heavy end of log #5, align it on the grate tine and set it on the fl at area of log #4 as shown. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 68 fl at area of log #1. The orientation of log #6 in relation to the grate tine is shown below. Notch engaged with Notch engaged with grate tine. grate tine. Log Assembly Installed. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 69: Fixed Glass Assembly

    Fully open on the glass frame top and bottom. • Make sure all sides are replaced properly. LATCHES BOTH BOTTOM AND TOP) GLASS ASSEMBLY Figure 14.3 Fixed Glass Assembly Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 70: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. d. Module voltage output / Valve/Pilot Verify battery voltage is at least 2.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 2.7. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 71 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fi ne. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 72: Reference Materials

    GAS LINE ACCESS FRONT VIEW RIGHT VIEW LEFT VIEW Location Inches Millimeters Location Inches Millimeters 1-1/2 42-1/2 1080 24-1/2 33-1/2 9-1/2 2-1/8 4-1/8 34-5/8 4-1/4 Figure 16.1 See-Through Dimensions Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 73 GAS LINE ACCESS FRONT VIEW RIGHT VIEW LEFT VIEW Location Inches Millimeters Location Inches Millimeters 1-1/2 40-1/2 1029 24-1/2 33-1/2 9-1/2 2-1/8 4-1/8 34-5/8 4-1/4 Figure 16.2 Pier Dimensions Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 74: Vent Components Diagrams

    14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.3 DVP vent components Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 75 79 mm 117 mm Length 5-3/8 in. 9-3/8 in. DVP-TRAP Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC1 DVP-HPC2 Figure 16.4 DVP vent components Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 76 13-7/8 in. 9-1/2 in. 26 in. (352 mm) (241 mm) 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS  Figure 16.5 DVP vent components Cap Shield Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 77 1 in. (25 mm) (222 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) 1-5/8 in. (41 mm) DVP-FBHT FireBrickTermination Cap DVP-HPC High Performance Cap Figure 16.6 DVP Vent Components Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 78 9-3/16 IN. (233 mm) 13-5/8 16-11/16 IN. 16-11/16 IN. (346 mm) 424 mm (424 mm) 12-1/2 IN. (318 mm) SLP-LPC SLP Low Profi le Cap Figure 16.7 Vent Components Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 79 8-11/16 in. 1-1/2 in. 5-1/2 in. 12 in. 220 mm 38 mm 305 mm 146 mm SLP-WS SLP-FS Wall Shield Firestop Ceiling Firestop Figure 16.8 SLP Series Vent Components Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 80 PVK-80 (For use with IPI and DSI appliances only.) DVP-FBHT 26 in. DVP-FBHT SL-2DVP 660 mm SLP90 DVP-HSM-B Extended Heat Shield Figure 16.9 SLP Series Vent Components ASSEMBLY Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 81 1 in. (25 mm) 13-1/2 in. 343 mm 7-3/4 to 10-3/8 in. (197 to 264 mm) DVP-FBHT SLK-SNKD Horizontal Snorkel Termination Cap Termination Cap Figure 16.10 SLP Series Vent Components Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 82 Refractory (Air Passage Side) 2129-016 Junction Box Bracket 2128-128 Junction Box 4021-013 Surround Overlay (contains overlay for top, bottom and sides) SRV2128-FACE Additional service part numbers appear on following page. 3/13 Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 83 Refractory 2129-016 Junction Box Bracket 2128-128 Junction Box 4021-013 Surround Overlay (contains overlay for top, bottom and sides) SRV2130-FACE Additional service part numbers appear on following page. 3/13 Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 84 16.14 Solenoid HTI-17-006 16.15 Controls Plate 2176-121 16.16 On/Off Rocker Switch 060-511 16.17 Control Box HTI-13-007 16.18 Battery Pack 593-594A Additional service part numbers appear on following page. Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 85: Service Parts List

    Wire Wall Switch 2095-550 Conversion Kit NG NGK-MS36 Conversion Kit LP LPK-MS36 Pilot Orifi ce NG 593-528 Pilot Orifi ce LP 593-527 Regulator NG NGK-DXV Regulator LP LPK-DXV Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...
  • Page 86: Contact Information

    5890485, 5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945B Printed in U.S.A. - Copyright 2013 Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13...

This manual is also suitable for:

St-36trlp-ipiPier-36tr-ipiPier-36trlp-ipi

Table of Contents