Installation
Instructions
PREPARATION
TOOLS AND MATERIALS
YOU WILL NEED
o
Saw
,
Flat-blade
screwdriver
Electrician's
pliers
.
Duct tape
Measuring tape or scale
.
Carpenter's
square
,
7/16" wrench or socket set
,
Drill and drill bit
,
Sheet metal screws
,
Junction
box*
,
3/4" flexible conduit*
,
Electrical wire per local code*
,
Wire nuts*
,
Ductwork
*NOTE: Electrical installation
kit JXCK89 may be
ordered separately
and includes all the ports
necessary to connect the cooktop to typical
rough-in wiring.
CAUTION:
FOR PERSONAL
SAFETY,
REMOVE
HOUSE FUSE OR OPEN CIRCUIT
BREAKER BEFORE PREPARING JUNCTION
BOX.
ELECTRICAL REQUIREMENTS
This appliance must be supplied with the proper voltage
and frequency, as listed in these Installation Instructions,
and connected to an individual, properly grounded branch
circuit, protected by a 40-amp circuit breaker or time delay
fuses.
All wire connections must be made in accordance with
local codes and properly insulated. Check with your local
utility for governing electrical codes and ordinances. In the
absence of local electrical codes, the National Electrical
Code,ANSI/NFPANo. 70 - Latest Edition, governing electric
range installations, must be followed.
A copy of the National Electrical Codecan be obtained by
writing to:
National Fire Protection Association
Batterymarch Park
Quincy, IVlA 02260
EffectiveJanuary 1, 1996,the National Electrical Code
requires that new, but not existing, construction utilize a
four-conductor connection to an electric range. When
installing an electric range in new construction, follow
the instructions in NEWCONSTRUCTION A ND FOUR-
CONDUCTOR BRANCH CIRCUIT CONNECTION.
You must use a three-wire, single-phase AC208Y/&20Volt
or 2/40/120Volt, 60 Hertz electrical system with separate
ground. If you connect to aluminum wiring, properly
installed connectors approved for use with aluminum
wiring must be used.
30" COOKTOP
(DIMENSIONS
FOR REFERENCE
ONLY)
Unitshown fully assembled.
227_d'
(22_16" SS)_,_
29_"
-,9
(30"_5)
_
$
2Y16"
I
(2_" ss)
._
28sA,,
Unit must be vented to the outside!