Montigo L38DF series Installation & Maintenance Manual page 9

Flush indoor gas fireplace
Table of Contents

Advertisement

f i r e f e a t u r e
Example 2:
.
45° Corner Installation. (Only available using Top Vent)
Attach a PEL-90 (90° elbow) directly onto the flue collar, and attach
it to the PEL-45 (45° elbow). Cut the PXT-18 to suit and insert it into
the PEL-45. Slide the fireplace into position, and then connect it to
the exterior termination.
Figure 11. Corner installation.
45° or less Corner Installation. (Only available using Top Vent).
Use a PTO-3 termination and an PFL-1 or PFL-2 (12" or 24"
compressed length) and a frame, if appropriate. Flex may be turned to
obtain desired degree of angle required but must not exceed 45°.
Figure 12. Flex installation.
Important: Corner Installation is available
for L38DF Top Vent Units Only.
Part No. XG0180 - 081009
Installation
Horizontal Venting
PXT-18
PEL-45 Elbow
PEXT Section
PEL-90 Elbow
Figure 13. Typical Top Vent installation. The solid sections can be used in
Example 3:
Rigid sections and an elbow used in conjunction with 3 ft. flex section
(PFL-3) will, when extended in a five foot chase, allow for a maximum
horizontal run of twelve and one-half feet from the centre of the fireplace
to outside wall and a minimum of 7'6" when retracted in opposite direction
(see Figure 12 and 13).
"C" flex sections and "D" rigid sections may be used in conjunction with
one another to obtain different possible horizontal length installations.
NOTE: Flex section with no vertical rise must not exceed maximum
horizontal length of 3 feet (see Figure 14). Flex runs over 6' feet must
fall within the limits set by the venting graph, and must have a minimum
vertical rise of 3" per foot of flex.
Figure 14. Extended Installation using a combination of solid and flex
L38DF Flush Indoor Gas Fireplace
various combinations to obtain the desired vent run. The vent
run must fall within the limits set by the venting graph.
venting. Use the vent graph to determine your allowable
run, then select appropriate components.
90° Elbow
RHS8
Termination
RHS8