Section 2: Power Supply - Grizzly G1095 Owner's Manual

1-hp power feeder w/4-rollers & 4-speeds
Hide thumbs Also See for G1095:
Table of Contents

Advertisement

SECTION 2: POWER SUPPLY

Availability
Electrocution,
equipment damage may
occur if machine is not
correctly grounded and
connected to the power
supply.
Full-Load Current Rating
G1095 at 220V, 1-Phase ...................... 4.2/2.5A
G1096 at 220V, 3-Phase ...................... 3.4/2.5A
G1095 Circuit Requirements
Nominal Voltage ........................................220V
Cycle ..........................................................60 Hz
Phase .................................................... 1-Phase
Circuit Rating ...................................... 15 Amps
Plug/Receptacle ............................. NEMA 6-15
G1096 Circuit Requirements
fire,
or
Nominal Voltage ........................................220V
Cycle ..........................................................60 Hz
Phase .................................................... 3-Phase
Circuit Rating ...................................... 15 Amps
Plug/Receptacle ............................NEMA 15-15
For your own safety and protection of
property, consult an electrician if you are
unsure about wiring practices or electrical
codes in your area.
Note: The circuit requirements listed in this man-
ual apply to a dedicated circuit—where only one
machine will be running at a time. If this machine
will be connected to a shared circuit where mul-
tiple machines will be running at the same time,
consult a qualified electrician to ensure that the
circuit is properly sized for safe operation.

Advertisement

Table of Contents
loading

This manual is also suitable for:

G1096

Table of Contents