Drive Acoustics - Seagate U Series Product Manual

U series family ultra ata interface drives
Hide thumbs Also See for U Series:
Table of Contents

Advertisement

U Series Family Product Manual, Rev. B
1.8.6.1 Operating vibration
The following table lists the maximum vibration levels that the drive may
experience while meeting the performance standards specified in this
document.
5–21 Hz
0.02-inch displacement (peak to peak)
22–350 Hz
0.5 Gs acceleration (zero to peak)
351–500 Hz
0.25 Gs acceleration (zero to peak)
1.8.6.2 Nonoperating vibration
The following table lists the maximum nonoperating vibration that the
drive may experience without incurring physical damage or degradation
in performance when subsequently put into operation.
5–21 Hz
0.2-inch displacement (peak to peak)
22–350 Hz
5.0 Gs acceleration (zero to peak)
351–500 Hz
1.0 Gs acceleration (zero to peak)

1.9 Drive acoustics

Drive acoustics are measured as overall A-weighted acoustic sound
power levels (no pure tones). All measurements are generally consistent
with ISO document 7779. Sound power measurements were taken
under essentially free-field conditions over a reflecting plane. For all
tests, the drive was oriented with the cover facing upward.
Note. For seek mode tests, the drive was placed in seek mode only.
The number of seeks per second is defined by the following
equation:
Number of seeks per second = 0.4 / (average latency + average access time)
ST380020A, ST360020A, ST340810A and ST320410A
Acoustic mode
Idle
Sound power (bels) 3.0 (typ)
3.3 (max)
Quiet Seek
Performance Seek
3.2 (typ)
3.4 (typ)
3.5 (max)
3.7 (max)
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

St380020aSt360020aSt340810aSt320410a

Table of Contents