Electromagnetic Immunity; Reliability - Seagate Barracuda ATA II Family Product Manual

Barracuda ata ii family ultra ata interface drives
Hide thumbs Also See for Barracuda ATA II Family:
Table of Contents

Advertisement

14
Barracuda ATA II Family Product Manual, Rev. B

1.10 Electromagnetic immunity

When properly installed in a representative host system, the drive
operates without errors or degradation in performance when subjected
to the radio frequency (RF) environments defined in the following table:
Test
Description
Electrostatic
Contact, HCP, VCP:
Air:
8 kV
discharge
Radiated RF
80 to 1000 MHz, 3 V/m, 80%
immunity
AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse
modulation @ 200 Hz
Electrical fast
kV on AC mains,
transient
on external I/O
Surge
kV differential,
immunity
common, AC mains
Conducted
150 kHz to 80 MHz, 3 Vrms,
RF immunity
80% AM with 1 kHz sine
Voltage dips,
0% open, 5 seconds
interrupts
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds

1.11 Reliability

Nonrecoverable read errors
Mean time between failures
Contact start-stop cycles
Preventive maintenance
Performance
Level
4 kV;
B
A
kV
B
kV
B
A
C
C
C
B
14
1 per 10
bits read, max
500,000 power-on hours
(nominal power, 25°C ambient temper-
ature)
50,000 cycles
(at nominal voltage and temperature,
with 60 cycles per hour and a 50% duty
cycle)
None required
Reference
Standard
EN 61000-4-2: 95
EN 61000-4-3: 96
ENV 50204: 95
EN 61000-4-4: 95
EN 61000-4-5: 95
EN 61000-4-6: 97
EN 61000-4-11: 94

Advertisement

Table of Contents
loading

This manual is also suitable for:

St330630aSt320420aSt315320aSt310210a

Table of Contents