Chapter 7. Self-Diagnosis Mode (Only For Sj-Pt56R) - Sharp SJ-PT56R-HS Service Manual

Hide thumbs Also See for SJ-PT56R-HS:
Table of Contents

Advertisement

CHAPTER 7.
SJPT56RHS
SELF-DIAGNOSIS MODE (Only for SJ-PT56R)
1. Entering method of the mode
1) Press the [Select] button on the control panel over 5 seconds at the opening condition of
the freezer and refrigerating room doors.
2) With a beep sound of buzzer, the self-diagnosis mode is entered. When the self-diagnosis
mode is not entered by the above operation, defect of Door SW system can be considered.
2. When the self-diagnosis mode is entered, the following movements will be made. Forced release operation is not prepared for the self-diagnosis
mode. It returns to the normal movement after a lapse of 2 minutes.
When the self-diagnosis mode is entered, beep sound for reminding of closing the door must not be sounded for 20 minutes.
Defect and various conditions are displayed by [ON/OFF of buzzer].
Defect and various conditions are displayed on the control panel. In case of plural defects and various conditions, these are displayed one after
another by button operation and all contents are notified.
3. Display of self-diagnosis
Display example of control panel (at the defect of F-thermistor system)
F
R
R
Result of diagnosis
Buzzer notice example; (at defrost defect, 2 times of 0.5 second ON)
ON
Buzzer
OFF
3 seconds stop
Move to the previous display
Move to the next display
0.5 second 0.5 second
3 seconds stop
0.5 second stop
Service Manual
0.5 second 0.5 second
Repeating
0.5 second stop
7 – 1
SJPT56RHS
F
R
R
Select button

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sj-t52r-sSj-t56r-sSj-pt56rSj-t56rSj-t52r

Table of Contents