CABLE CONNECTIONS

The PL07 does not use conventional screw terminals for wiring connections, but
uses cage clamp terminals. The cage clamp terminals are spring loaded and
provide a very quick and secure method of making all the electrical connections
to the module.
Please take the following steps to make the wiring connections to the PL07:
1. Prepare the cable ends:
!
2. Insert the cable into the cable grip:
3. Route the conductors through the wire guides:
PL07 INSTRUCTION MANUAL
• Strip outer sheath to a distance
of 110mm
• Strip 10mm from the ends of
each conductor sheath
It is very important that these
dimensions are followed to ensure
correct connection to the module.
mm
10/9/10
10:03
7