Do It Yourself Service Chart
Problem: Red Caution Light Lit, Loss of Suction or Overheating
of the Motor
Cause:
Clogged Flat Disc Filter
Obstructed Hose
Obstructed Wand
Obstruction at neck of
Power Nozzle
Filter Cone coated with
extremely fine dust
Problem: Machine will not operate
Cause:
Plug not connected to
outlet, or a faulty one
Motor overheated and
tripped automatic shut-off
Damaged switch
Damaged motor
Damaged power cord plug
Correction:
Replace Flat Disc Filter.
See instructions (6) under
"Power Nozzle Does Not Operate."
Run long wire or a straightened
coat hanger through wand.
See instruction (4) under "Power
Nozzle Does Not Operate"
Empty Dirt Container and
replace Filter Cone. Flat Disc
Filter may also need to be replaced.
Correction:
Insert plug firmly into wall outlet or
try another outlet.
Turn power switch to "O" off and
unplug power cord from wall. Let
unit cool. Check for blockage in
attachment. Filter cones may also
need to be replaced.
Call your local FILTERQUEEN
for service.
Call your local FILTERQUEEN
for service.
Call your local FILTERQUEEN
for service.