Hitachi N 5008AB Instruction Manual page 20

Table of Contents

Advertisement

Available languages

Available languages

English
Operator troubleshooting
Most minor problems can be resolved quickly and easily using the table below.
If problems persist, contact a Hitachi authorized service center for assistance.
PROBLEM
Piston Ass'y does not
return to full up position
at end of cycle.
Weak drive.
Slow to cycle.
Skipping staples.
Intermittent feed.
Staples jam.
Drives properly during
normal operation, but does
not drive fully at faster
stapling speeds.
CHECK METHOD
Check air pressure.
Piston O-ring cut or
heavily worn?
Driver blade bent or
damaged at the driving
end?
Air exhaust clogged with
dirt or sludged lubricant?
———
Check air pressure.
Driver blade worn at the tip?
Piston O-ring worm or
damaged?
———
———
Staple feeder damaged?
Ribbon spring weakend or
damaged?
Staple guide obstructed
by dirt?
Check for proper staples.
Driver blade damaged
at the driving end?
Check inside diameter of
air hose.
— 20 —
CORRECTION
Adjust at 70—120psi.
(4.9—8.3bar 5—8.5kgf/cm
Contact Hitachi for
replacement.
Clean air exhaust.
Use Hitachi pneumatic tool
lubricant.
Increase air pressure.
(Do not exceed 120 psi
(8.3 bar 8.5 kgf/cm
Contact Hitachi for
replacement.
Use Hitachi pneumatic tool
lubricant.
Use Hitachi pneumatic tool
lubricant.
Replace staple feeder.
Replace ribbon spring.
Clean staple guide.
Use only recommended
staples.
Contact Hitachi for
replacement.
Use larger air hose.