SPECIFICATIONS AC-215A
AC Current Capacity
Input: 10 Amp capacity required
Output: 10 Amp RMS (both outlets combined)
AC Noise Attenuation, Transverse (Differential) Mode
>40dB @ 100kHz
>50dB @ 500kHz
(linear attenuation curve from 0.05 to 100Ω line impedance)
Transient Voltage Surge Suppression
120VAC
Series Multi-Stage Protection
Non-Sacrificial with Zero Ground Contamination
188V peak clamping @ 6000V/3000A input
Extreme Voltage Shutdown
137 VAC typically
Dimensions & Weight
1.75" (H) x 5" (W) x 8.5" (D), 3 lbs.
Safety Agency Listing
cTUVus
POWER CORD INLET SECURITY CLAMP
To attach or detach the AC power cord security clamp, simply assemble or
disassemble as shown in the above illustration. Place clamp together as shown,
and secure screws in the provided holes to lock the power cord in place.
Loosen screws and remove clamp from unit to detach.