Download Print this page
Furman ASD-120 Owner's Manual
Furman ASD-120 Owner's Manual

Furman ASD-120 Owner's Manual

Sequenced power distro, 120a
Hide thumbs Also See for ASD-120:

Advertisement

Quick Links

A S D - 1 2 0 – S e q u e n c e D P o w e r D i S t r o
ASD-120
SequenceD Power DiStro, 120A
Ac DiStro'S

Advertisement

loading
Need help?

Need help?

Do you have a question about the ASD-120 and is the answer not in the manual?

Questions and answers

Summary of Contents for Furman ASD-120

  • Page 1 A S D - 1 2 0 – S e q u e n c e D P o w e r D i S t r o ASD-120 SequenceD Power DiStro, 120A Ac DiStro’S...
  • Page 2 A S D - 1 2 0 – S e q u e n c e D P o w e r D i S t r o Congratulations on your purchase of a Furman ASD-120 Sequenced Power Distro. Please read this manual completely before installing your ASD-120, or at the very least review the quick start pages.
  • Page 3 A S D - 1 2 0 – S e q u e n c e D P o w e r D i S t r o q u i c K S tA r t REMOTE inSTAllATiOn Of An ASD-120 S CE NARIO - 1 T YP IC AL PR OF ES S I O NAL INS TALLAT ION R EMOT E ASD-120 TR IG G ER ED BY HOUS E P S-8R , P S-PR O ACT IV AT ED BY PS - R EL ASD-120...
  • Page 4 R EMOTE DELAY The above diagram shows examples of using furman remote products in conjunction with one another. With this configuration, you will be turning on an MP-20Q first, then the MP-20 (1) and using the delay feature of the MP-20 (1) to turn on a second MP-20 (2). This whole sequence will be triggered with the RS- 1, RS-2, or computer controller.
  • Page 5 K S tA r t fuRMAn SOunD REMOTE TERMinAlS MOMENTARY REMOTE SWITCHES All furman remote terminals share the same labeling. for remote control only one contact closure is required for triggering the units. The status and ground terminals are strictly for an STAT indicator lED (light Emitting Diode).
  • Page 6 A S D - 1 2 0 – S e q u e n c e D P o w e r D i S t r o F e At u r e S and video shoots, etc.— any situation where AC power must be distributed to multiple circuits and a hard-wired, built-in system is missing, inadequate, or 120 amp total load...
  • Page 7 A S D - 1 2 0 – S e q u e n c e D P o w e r D i S t r o (or openings) that can be used to control furman 1. Determine the power source. in north America,...
  • Page 8 A S D - 1 2 0 – S e q u e n c e D P o w e r D i S t r o if the cable is to be moved from location to location Ground = Green or Green with Yellow Stripe, X frequently, we suggest you make it at least a few = Black (hot), Y = Red (hot), W = White (neutral).
  • Page 9 A S D - 1 2 0 – S e q u e n c e D P o w e r D i S t r o cover. This completes the internal wiring of the adjustable with a trim pot, with a range of 0.2 to > 12 ASD-120.
  • Page 10 Momentary Mode on the of the chassis and signal grounds of the ASD-120, for furman PowerPort, MiniPorts, Powerlink and PS-PRO easy interfacing to virtually any other device that could and PS-8R Power Sequencers. Remote inputs (ReM, act as a slave to follow the ASD-120.
  • Page 11: Momentary Mode

    ASD-120’s remote operation. Maintained switches, MOMEnTARY MODE such as most toggle switches and push-on/push-off button switches, and including the furman RS-1 wall In Momentary Mode, the ASD-120 has “memory”– it mount key lock switch, are open until actuated, then only needs a momentary signal to change its state stay closed until actuated again.
  • Page 12: Status Output

    On position, check the polarity and reverse affecting the other units. the lED leads if it is wrong. if a furman RS-1 is the The STATuS lines work the same in either mode. Each controlling switch, contact furman’s Tech Support reflects the true state of the sequence control circuit department for the proper wiring diagrams.
  • Page 13: Compatibility With Other Furman Products

    ASD-120’s in sync. circuits are trying to turn the unit off. (Other furman products blink one of their status lights to indicate the A D D i t i o n A L remote status.)
  • Page 14 WARRANTIeS, shall not be relied upon by Purchaser, by mail or on-line at the furman website. If the Product and are not a part of the contract for sale or this limited does not conform to this limited Warranty during warranty.
  • Page 15 A S D - 1 2 0 – S e q u e n c e D P o w e r D i S t r o...
  • Page 16 Construction: Steel chassis, zinc chromate plating; .125" brushed and black anodized aluminum front panel. Power Consumption at 130 VAC: 23 watts Safety information: All current-carrying components furman Sound, llC. 1690 Corporate Circle Petaluma, California 94954-6919 USA Phone: 707-763-1010 fax: 707-763-1310 Web: www.furmansound.com...