Burner input requirements
Elevations up to 10,000 feet (3,048 meters):
The design of this dryer is certified by CSA International for
use at altitudes up to 10,000 ft (3,048 m) above sea level at
the B.T.U. rating indicated on the model/serial number plate.
Burner input adjustments
are not required when the dryer is
operated up to this elevation.
Elevations above 10,000 feet (3,048 meters):
When installed above 10,000 ft (3,048 m) a 4% reduction of
the burner B.T.U. rating shown on the model/serial
number
plate is required for each 1,000 ft (305 m) increase in
elevation.
Gas supply pressure testing
The dryer must be disconnected
from the gas supply piping
system during any pressure testing.
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metaJ foil vent.
Failure to follow these instructions
can result in
death or fire.
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
4 in. (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE
TM
vent products are recommended.
DURASAFF Mvent products can be purchased from your dealer
or by calling Whirlpool Parts and Accessories.
For more
information, see the "Assistance
or Service" section of this
manual.
IMPORTANT: Observe all governing codes and ordinances.
(mproper
venting
can cause moisture
and mintto commect
indoors,
which may result in:
[]
Moisture damage to woodwork,
furniture, paint, wall-
paper, carpets, etc=
[]
Housecleaning
problems and health probIems=
Use a heavy metal vent. Do not use plastic or metal foil vent.
Rigid metal vent is recommended
to prevent crushing and
kinking.
Flexible metal vent must be fully extended and supported
when
the dryer is in its final position. Remove excess flexible metal vent
to avoid sagging and kinking that can result in reduced airflow
and poor performance.
An exhaust hood should cap the vent to prevent rodents and
insects from entering the home.
Exhaust hood must be at least 12 in. (30.5 cm) from the ground or
any object that is in the path of the exhaust (such as flowers,
rocks or bushes, etc.).
If using an existing vent system, clean lint from the entire length
of the system and make sure exhaust hood is not plugged with
lint. Replace any plastic or metal foil vent with rigid metal or
flexible metal vent.
Typical exhaust
installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
2
1
.....................................
3
i
....................6
.....................................
7
1. Dryer
2. Elbow
3. Wall
4. Exhaust hood
5. Clamps
6. Rigid metal or flexible
metal vent
7. Vent length necessary
to connect elbows
8. Exhaust outlet
The dryer exhaust must not be connected
into any gas vent,
chimney, wall, ceiling, or a concealed
space of a building.
Do not use an exhaust hood with a magnetic latch.
Do not install flexible metal vent in enclosed walls, ceilings or
floors.
Use clamps to seal all joints. Exhaust vent must not be
connected or secured with screws or other fastening devices
which extend into the interior of the duct. Do not use duct
tape.