Download Print this page

Gianni Industries DG-101 Operation Manual

Digital keypad

Advertisement

Quick Links

It can be mounted directly in ANSI
electrical box (mortise mount)
Ⅰ. Features
1. Memory volume up to 49+50 PINs, 5-digit codes
2. Dual relays to control door lock and other security devices
3. Additional input for anti-tailgating function to ensure high security access control
4. 3 LED indicator & buzzer for status indication
5. Fully programmable via 4X3 matrix keypad
6. Non-volatile memory allows remaining all setting codes in the event of total power
failure
7. Lockout function
Ⅱ. Specifications
Operating Voltage 12~24VDC
Current Draw Holding:15mA, Pull in: 60 mA @12VDC
Keypad 12 buttons (0~9,*,#)
LED Status Indication 3 LED indicator display (Red/Yellow/Green)
Relay Strike Time
Relay Electric Current 0.4A @ 120VAC or 2A@30 VDC
Memory Volume
EPROM
Casing material ABS V0
Ambient Humidity 0%~95% (Non-condensing)
Operating Temperature -20℃~+70℃
Copyright Gianni Industries, Inc. All Rights Reserved.
P-MU-DG101 Ver. D Publish:2009.12.24
DG-101 Digital Keypad
Operation Manual
1 contact for Request-To-Exit button (N.O.)
Input
1 contact for door reed switch
Output 2 relays(Dry contacts: N.O./N.C./Com.)
Sign: Relay 1(*100), Relay 2(*200)
01~99 seconds or Toggle Mode (00)
49+50PINs(*001~*099)
Relay 1 is controlled by user*001~*049(*100)
Relay 2 is controlled by user*050~*099(*200)
Non-volatile memory allows remaining all setting codes in the
event of total power failure.
With SMB-750 (optional) for surface
mount.
Page: 1/ 3

Advertisement

loading

Summary of Contents for Gianni Industries DG-101

  • Page 1: Specifications

    Non-volatile memory allows remaining all setting codes in the EPROM event of total power failure. Casing material ABS V0 Ambient Humidity 0%~95% (Non-condensing) Operating Temperature -20℃~+70℃ Copyright Gianni Industries, Inc. All Rights Reserved. P-MU-DG101 Ver. D Publish:2009.12.24 Page: 1/ 3...
  • Page 2: Status Indication

    Additional input for anti-tailgating function to ensure high security access control. If the relay strike time set to 10 seconds and the door is closed in 3 seconds, the 7 seconds will be cut off automatically. Copyright Gianni Industries, Inc. All Rights Reserved. P-MU-DG101 Ver. D Publish:2009.12.24 Page: 2/ 3...
  • Page 3: Operation Instruction

    1 year from the date of sale to the original customer. GEM policy is one of continual development and improvement; therefore GEM reserves the right to change specifications without notice. Copyright Gianni Industries, Inc. All Rights Reserved. P-MU-DG101 Ver. D Publish:2009.12.24 Page: 3/ 3...

This manual is also suitable for:

Gem dg-101