DG-25/26/27/101 Series Digital Keypad
It can be mounted directly in ANSI
electrical box (mortise mount)
I.
Features
1. Memory volume up to 49+50 PINs, 5-digit codes
2. Dual relays to control door lock and other security devices
3. Additional input for anti-tailgating function to ensure high security access control
4. 3 LED indicator & buzzer for status indication
5. Fully programmable via 4X3 matrix keypad
6. Non-volatile memory allows remaining all setting codes in the event of total power
failure
7. Lockout function
8. DG-25/26/27series are stainless steel casing with vandal resistant screws for
enhanced safety and durability.
9. DG-101 are ABS casing and can be mounted directly in ANSI electrical box (mortise
mount) or with SMB-500 for surface mount.
Copyright © All Rights Reserved.
P-MU-DG101 Ver.D Publish:2010.03.03
Operation Manual
DG-101
With SMB-500 (optional) for surface
mount.
Page: 1/ 4

Advertisement

loading

Summary of Contents for Gianni Industries DG-27 Series

  • Page 1 DG-25/26/27/101 Series Digital Keypad Operation Manual DG-101 It can be mounted directly in ANSI With SMB-500 (optional) for surface electrical box (mortise mount) mount. Features 1. Memory volume up to 49+50 PINs, 5-digit codes 2. Dual relays to control door lock and other security devices 3.
  • Page 2 II. Specifications Operating Voltage 12~24VDC DG-101/25/25WP/26/26WP/27/27WP Holding:10mA, Pull in: 40mA /12VDC Holding:10mA, Pull in: 40mA /24VDC Current Draw DG-25LD/26LD/27LD Holding:40mA, Pull in: 70mA /12VDC Holding:60mA, Pull in: 90mA /24VDC Keypad 12 buttons (0~9,*,#) LED Status Indication 3 LED indicator display (Red/Yellow/Green) 1 contact for Request-To-Exit button (N.O.) Input 1 contact for door reed switch...
  • Page 3 IV. Wiring Diagram ● DG-101 ● DG-25/26/27 Series Note:  The door strike or relay must have a varistor or a diode across the door strike terminals to suppress the back EMF of the strike – failure to do so will damage the relay contacts and electronic components, or even burns the controller.
  • Page 4 V. Operation Instruction  Enter Setting Mode Enter the master code twice (Default value:“12345”) to enter setting mode (2 Beeps) Note: 1. After 60 seconds if no data entered, it will automatically exit the setting mode. 2. The controller will be lockout for 60 seconds upon 32 consecutive master codes or invalid PINs attempt.

This manual is also suitable for:

Dg-26 seriesDg-25 seriesDg-101 series