PRODUCT DATASHEETS
Base Grille Water Filtration System
Model WF-L200V
Capacity
200 Gallons
(757 Liters)
Model WF-NL120V
Capacity
120 Gallons
(454 Liters)
System tested
and certified
by NSF International
against
NSF/ANSI
Standard
53
for the reduction
of Lead, Mercury,
Benzene,
p-dichlorobenzene,
O-Dichlorobenzene,
Toxaphene,
Ethyl Benzene,
1,2,4-trichlorobenzene
and
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine Taste and Odor and
Particulate
Class III.
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances
listed below. The concentration
of
the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the permissible limit for
water
leaving
the system,
as specified
in ANSI/NSF
42/53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Average%
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
_>50%
1.9 mg/L
2.0 mg/L + 10%
| 0.07 mg/L
0.06 mg/L
>75%
>75%
49333/mL
312/mL
98.7%
99.0%
Particulate Class Ill*
_>85%
At east 10,000 part c es/m 4 640/mL**
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Average%
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead:@ pH 6.5
0.01 mg/L
0.14 mg/U
0.15 mg/L _+10%
0.0014 mg/L
0.0011 mg/L
99.00%
99.21%
Lead: @ pH 8.5
0.01mg/L
0.15 mg/L t
0.15 mg/L
_+10%
0.0069 mg/L
0.0042 mg/L
95.40%%
97.20%
Mercury: @ pH 6.5
0.002 mg/L
0.0059 mg/L
0.006 mg/L _+10%
0.0009 mg/L
0.0004 mg/L
84.74%
93.22%
Mercury: @ pH 8.5
0.002 mg/L
0.0054 mg/L
0.006 mg/L
_+10%
0.0007mg/L
0.00043 mg/L
87.03%
92.03%
Benzene
0.005 mg/L
0.0157 mg/L
0.015 mg/L _+10%
0.002 mg/L
0.00083 mg/L
87.26%
94.71%
p-dichlorobenzene
0.075 mg/L
0.210 mg/L
0.225 mg/L _+10%
0.0005 mg/L
0.0005 mg/L
99.76%
99.76%
O-Dichlorobenzene
0.60
1.84
1.8 _+10%
0.20
0.0418
89.13
97.73
Toxaphene
0.003
0.0143
0.015 _+10%
0.0012
0.0010
91.60
93.00
Ethyl Benzene
0.70
2.00
2.1 _+10%
0.40
0.085
80.00
95.75
1,2,4- trichlorobenzene
0.07
0.232
0.21 _+10%
0.0041
0.0016
98.23
99.31
Test Parameters: pH =
(17.2°C).
It is essential that operational, maintenance, and filter
replacement requirements
be carried out for the product to
perform as advertised.
Model WF-L2OOV: The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter's rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended
that you
replace the filter. Use replacement filter L200V/NL120V,
part
#4396701. 2009 suggested retail price of $34.99 U.S.A./
$45.99 Canada. Prices are subject to change without notice.
Model WF-NL120V: Change the water filter every
6 months. Use replacement filter L200V / NL120V, part
#4396701. 2009 suggested retail price of $34.99 U.S.A./
$45.99 Canada. Prices are subject to change without notice.
7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection
before or after
the system.
Refer to the front
cover
or "Accessories"
section
for the
Manufacturer's
name,
address
and telephone
number.
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 GPM (1.9 L/min.)
@ 60 psi
*Class III particle size: > 5 to < 15 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
tThese contaminants
are not necessarily in your water supply. Performance
may vary based on local water conditions.
® NSF is a registered trademark