Power Supply Requirements for Blades in DCX/DCX-4S
Blades
Type of Blade
FC10-6
, FC8-
Port Blade
1
16, FC8-32,
FC 8-48, FC8-
64
FR4-18i
Intelligent
1
Blade
FS8-18,
Intelligent
FX8-24,
Blade
FCOE10-24
1. Note that FC10-6 and FR4-18i are not supported with FOS v7.1 or later
Fabric OS v7.1.0a Release Notes v1.0
DCX/DCX-4S
DCX/DCX-4S
@110 VAC
@200-240 VAC
(Redundant
configurations)
configurations)
2 Power
2 Power Supplies
Supplies
Not Supported
2 Power Supplies
Not Supported
DCX: 2 or 4 Power
Supplies
DCX-4S: 2 Power
Supplies
Table 3 Power Supply Requirements for DCX and DCX-4S
(Redundant
Distribute the Power Supplies
evenly to 2 different AC
connections for redundancy.
For DCX with three or more
FS8-18 Blades, (2+2)
220VAC Power Supplies are
required for redundancy.
For DCX with one or two
FS8-18 Blades, (2) 220VAC
Power Supplies are required
for redundancy.
For DCX-4S, (2) 220VAC
Power Supplies provide
redundant configuration
with any supported number
of FS8-18 Blades.
For both DCX and DCX-4S
with FX8-24 blades, (1+1)
220VAC Power Supplies are
required for redundancy.