Payne PG8M Owner's Manual page 4

Induced combustion gas furnace
Table of Contents

Advertisement

i.- I
"---1
Fig. 4 - Close Valve
3. Turn OFF electrical
supply to the furnace.
See Fig. 5.
A06188
Ag2185
Fig. 5 - 1hrn
Off Electrical
Supply
4. Remove
the outer
door by loosening
the thumbscrew
and
pulling
the door forward.
See Fig. 6.
©
©
_
_©_©_©
,__,_
i'" !
J
A02267
Fig. 8 - Control
Switch
to ON
8. Replace
the outer door and tighten
the thumbscrew.
See Fig.
11.
;'©
f"©
'j
A10303
Fig. 9 - Furnace
Door
Replaced
9. Turn ON the electrical
supply to the furnace.
See Fig. 10.
A10302
Fig. 6 - Remove
Furnace
Door
5. Turn the control switch on the gas control to the OFF position
and wait 5 minutes. See Fig. 7. Then smell for gas, including
near the floor. If you smell gas, STOP! Follow"B" on furnace
label. If you don't smell gas, go to next step.
7
OR
J
A02266
Fig. 7 - Control
Switch
to OFF
6. After waiting
5 minutes,
if you still smell gas, STOP!
Follow
the safety information
on the cover of this manual.
If you do
not smell gas, go to the next step.
7. Turn the control
switch to ON.
See Fig. 8.
Ag235g
Fig. 10 - Turn On Electrical Supply
10. Open the external manual gas valve. See Fig. 11.
Fig. 11 - Open Valve
A0618g
11. Set the room thermostat to a temperature
slightly
above the
room temperature.
This will automatically
signal the furnace
to start. The inducer motor will start and the hot surface igniter
will energize.
When hot, the igniter will have an orange glow.
12. After about 17 seconds, the gas valve permits gas to flow to the
main burners
where it is ignited.
Hot flames begin
to warm

Hide quick links: