Base Grille Water
Filtration
System
Model WF-LC400V/LC400V
Capacity 400 Gallons (1514 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, Nominal
Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction
of Lead, Mercury, Atrazine, Benzene, Toxaphene, p-dichlorobenzene,
2,
4-D, Cysts, Turbidity and Asbestos.
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances
listed below. The
concentration
of the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance
Reduction
NSF Reduction
Average
Aesthetic
Effects
Requirements
Influent
Chlorine Taste/Odor
_>50%
Nominal Particulate Class I*
_>85%
2.1 mg/L
5,366,667/mL
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Product
Minimum %
Average %
Concentration
Effluent
Water
Reduction
Reduction
2.0 mg/L _+10%
0.06 mg/L
0.05 mg/L
97.1%
97.6%
At least 10,000
99.9%
99.3%
2,300/mL
4,100/mL**
particles/mL
Influent Challenge
Maximum
Product
Minimum %
Average %
Reduction
Lead: (-®pH 6.5
Lead: @ pH 8.5
Mercury: @ pH 6.5
Mercury: @ pH 8.5
Benzene
p-dichlorobenzene
Toxaphene
Atrazine
2, 4-D
Asbestos
Cysts:_
Turbidity
Requirements
0.01 mg/L
0.01 mg/L
0.002 mg/L
0.002 mg/L
0.005 mg/L
0.075 mg/L
0.003 mg/L
0.003 mg/L
0.07 mg/L
99%
99.95%
0.5 NTU
Influent
0.16 mg/L1-
0.15 mg/L1-
0.0061 mg/L
0.0057 mg/L
0.0138 mg/L
0.220 mg/L
0.014 mg/L
0.009 mg/L
0.197 mg/L
26 x 107
111,000/mL
11.08 NTU
Concentration
0.15 mg/L_+ 10%
0.15 mg/L_+ 10%
0.006 mg/L _+10%
0.006 mg/L _+10%
0.015 _+10%
0.225 _+10%
0.015 _+10%
0.009 mg/L _+10%
0.215 _+10%
107to 108fibers/Llt
50,000/L min.
11 _+1 NTU
Effluent
0.001 mg/L
0.001 mg/L
0.0004 mg/L
0.0008 mg/L
0.0005 mg/L
0.0005 mg/L
0.0014 mg/L
0.0013 mg/L
0.058 mg/L
0.18 x 107 mg/L
1 mg/L
0.13 NTU
Water
0.001 mg/L
0.001 mg/L
0.0003 mg/L
0.00051 mg/L
0.005 mg/L
0.0005 mg/L
0.001 mg/L
0.00036 mg/L
0.0137 mg/L
0.18 x 107 mg/L
1 mg/L
0.078 NTU
Reduction
99.3%
99.2%
93.5%
85.8%
96.3%
99.7%
90%
85.6%
70.6%
99.93%
99.99%
98.8%
Reduction
99.35%
99.31%
96.7%
91.2%
96.3%
99.7%
92.96%
85.6%
93.06%
99.93%
99.99%
99.3%
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 63°F (17.2°C).
It is essential that operational, maintenance,
and filter
replacement requirements be carried out for the product to
perform as advertised.
Flush for 5 minutes prior to use.
Model WF-LC400V:
The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter's rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended
that you
replace the filter. Use replacement cartridge LC400V, part
#8212652. 2006 suggested retail price of $39.99 U.S.A./
$44.99 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection
before or after
the system. Systems certified for cyst reduction may be used
on disinfected
waters that may contain filterable cysts.
Refer to the front cover or "Accessories"
section for the
Manufacturer's
name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's
limited
warranty.
Note that while the testing was performed under standard
laboratory conditions, actual performance may vary.
Application Guidelines/Water
Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate
0.5 gpm (1.89 L/min.) @ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
1-These contaminants
are not necessarily in your water supply. Performance
may vary based on local water conditions.
1-1-Fibers greater than 10 um in length
SBased on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark
of NSF International.
13