Performance Data Sheets; Warranty - KitchenAid KSCS23FTWH00 Use & Care Manual

Counter depth
Hide thumbs Also See for KSCS23FTWH00:
Table of Contents

Advertisement

Available languages

Available languages

PERFORMANCE DATA SHEETS
Base Grille Water
Filtration
System
Model TlWB2LfTIRFWB2
Capacity 200 Gallons (758 Liters)
Model TlWB2/TIRFWB2
Capacity 200 Gallons (758 Liters)
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, Particulate
Class I*; and against
NSF/ANSI
Standard
53 for the
reduction
of Lead, Mercury, Atrazine,
Benzene,
Toxaphene,
O-Dichlorobenzene,
Cysts, Turbidity,
Asbestos,
Lindane,
Tetrachloroethylene,
Endrin, Alachlor,
Chlorobenzene
and Ethylbenzene.
This system
has been tested according
to NSF/ANSI
Standards
42 and 53 for the reduction
of the substances
listed below. The
concentration
of the indicated
substances
in water entering
the system was reduced
to a concentration
less than or equal to the
permissible
limit for water leaving the system,
as specified
in NSF/ANSl
Standards
42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine
Particulate Taste/Odor
Class I*
85%50%
reductionreduction
3533333#/mL2.0
mg/L
At2.0 least
mg/L10,O0O
-+ 10%
220000.08
mg/L
#/mL **
2.011567
mg/L # /mL
99.3895.93
99.6797.36
particles/mL
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: (-® pH 6.5
0.010 mg/L
150 ug/L
0.15 mg/L _+10%
1.0 ug/L
1 ug/L
99.33
99.33
Lead: @ pH 8.5
0.010 mg/L
157 ug/L
0.15 mg/L _+10%
2.0 ug/L
1.08 ug/L
98.72
99.31
Mercury: @ pH 6.5
0.002 mg/L
0.0058 mg/L
0.006 mg/L _+10%
0.0002 mg/L
0.0002 mg/L
96.53
96.53
Mercury: @ pH 8.5
0.002 mg/L
0.0057 mg/L
0.006 mg/L _+10%
0.0002 mg/L
0.0002 mg/L
96.5
96.5
Benzene
0.005 mg/L
15 ug/L
0.015 mg/L _+10%
0.5 ug/L
0.5 ug/L
96.67
96.67
O-Dichlorobenzene
0.6 mg/L
1750 ug/L
1.8 _+10%
1.0 ug/L
1.0 ug/L
99.94
99.94
Toxaphene
0.003 mg/L
15 ug/L
0.015 _+10%
1.0 ug/L
1.0 ug/L
93.33
93.33
Atrazine
0.003 mg/L
10 ug/L
0.009 mg/L _+10%
2 ug/L
2 ug/L
80.8
80.8
Asbestos
99%
101 MFL
107to 10Bfibers/L tt
0.17 MFL
0.17 MFL
99.83
99.83
Live Cysts _
>99.95%
120,000/L
50,000/L min.
8/L;
1/L;
99.99
>99.99
Turbidity
0.5 NTU
11.4 NTU
11 _+1 NTU
0.41 NTU
0.24 NTU
96.4
97.89
Alachlor
0.002 mg/L
41.3 ug/L
0.04 _+10%
0.2 ug/L
0.2 ug/L
99.52
99.52
Endrin
0.002 mg/L
5.9 ug/L
0.006 _+10%
0.5 ug/L
0.3 ug/L
91.5
95.47
Ethylbenzene
0.7 mg/L
1867 ug/L
2.1 _+10%
0.70 ug/L
0.0588 ug/L
99.96
100
Lindane
0.002 mg/L
1.9 ug/L
0.002 _+10%
0.02 ug/L
0.02 ug/L
98.93
98.93
Chlorobenzene
0.6 mg/L
2.0 ug/L
2.0 _+10%
0.0005 ug/L
0.0005 ug/L
99.98
99.98
Tetrachloroethylene
0.005 mg/L
14.2 ug/L
0.015 _+10%
0.5 ug/L
0.5 ug/L
96.47
96.47
Test Parameters:
pH = 7.5 + 0.5 unless otherwise
noted.
Flow = 0.5 gpm (1.9 Lpm). Pressure
= 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C).
It is essential
that operational,
maintenance,
and filter
replacement
requirements
be carried
out for the product
to
perform
as advertised.
Use replacement
cartridge
T1RFWB2,
part #4396711.
2007 suggested
retail price of $39.99 U.S.A./S49.99
Canada.
Prices are subject to change without
notice.
Model
TlWB2L:
Style
1 - When the filter indicator
reads 10%,
order a new filter. When the filter indicator
reads 0%, it is
recommended
that you replace the filter.
Style 2 - When the filter indicator
light changes
from green to
yellow, order a new filter. When the filter indicator
light changes
from yellow to red, it is recommended
that you replace the filter.
Model TIWB2:
Change the water filter cartridge
every 6 months
depending
upon your usage. If the water flow to the water
dispenser
or ice maker decreases
noticeably
before 6 months
have passed, replace the water filter cartridge
more often.
These contaminants
are not necessarily
in your water supply.
While testing
was performed
under standard
laboratory
conditions,
actual performance
may vary.
The product
is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown
quality without
adequate
disinfection
before or after the
system.
Systems
certified
for cyst reduction
may be used on
disinfected
waters
that may contain
filterable
cysts.
Refer to the back cover or "Accessories"
section
for the
Manufacturer's
name, address and telephone
number.
Refer to the "Warranty"
section for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 gpm (1.9 L/min.) @ 60 psi.
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
ttFibers greater than 10 um in length
_Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark
of NSF International.
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents