Avoid
Service
Checklist
OCCURRENCE
Air conditioner will not operate.
Air from unit does not feel cold
enough.
Air conditioner
cooling,
but room is
too warm
- ice forming
on cooling
coil behind decorative
front.
Air conditioner
cooling, but room
is
too
warm
-- NO
ice forming
on
cooling coil behind decorative
front.
Air
conditioner
turns
on
and
off
rapidly.
Noise when unit is cooling.
Water
dripping
INSIDE when
unit is
cooling.
Water dripping
OUTSIDE when unit is
cooling.
Before calling for service,
review this list. It may save you time and expense. This tist
includes common
occurrences that are not the result of defective workmanship
or
materials
in this appliance.
SOLUTION
Wall plug disconnected
Push plug firmly into wall outlet.
House fuse blown or circuit breaker tripped. Replace fuse wit h time delay type or reset circuit breaker.
Selector Control in OFFposition Turn selector to ON (somemodels)or the desired FAN or COOL setting.
Unit turned off by moving thermostat
to a higher number and then immediately turning
back to
a colder number. Wait approximately
3 minutes.
Listen for compressor to start.
Unit turned off and then on too quickly. Turn unit off and wait 3 minutes before restarting.
Thermostat
set too tow. Adjust thermostat
to higher number for cooling.
Turn selector to a higher FAN or COOL position
Thermostat
set too warm. Set thermostat
to colder temperature.
Room temperature
below 70"F (21 °C). Cooling may not occur until room temperature
rises above
70"F (21°c).
Temperature sensing tube touching cold coil, located behind air filter. Straighten tube away from coil
Outdoor temperature
below 70"F (21 °C), To defrost the coil, set selector to FAN position. Then,
set thermostat
to warmer position.
Air filter may be dirty. Clean filter.
Refer to Care and CIeaning section. To defrost,
set selector
to FAN.
Thermostat set too cold for night-time
cooling. To defrost the coil, set selector to a FAN position.
Then, set thermostat
to a warmer
position.
Dirty air filter-+air restricted, Clean air filter. Refer to Care and Cleaning section.
Thermostat
set too warm. Turn thermostat
clockwise to a colder setting.
Thermostat
set on low number. Turn thermostat to higher number.
Vent set at OPEN position.
Set vent at CLOSED position for maximum cooling.
Air directional
Iouvres positioned
improperly. Position Iouvres for better air distribution.
Front of unit is blocked by drapes, blinds, furniture,
etc. -- restricts air distribution. Clear blockage
in front of unit,
Doors. windows,
registers, etc open --cold air escapes. Close doors, windows,
registers, etc.
Unit recently turned on in hot room. Allow additional
time to remove "stored heat" from walls.
ceiling, floor and furniture.
Dirty air filter-- air restricted. Clean air filter,
Outside temperature
extremely hot. Set FAN on high speed to bring air past cooting coils more
frequently.
Air movement
sound. This is normal.
If too loud, turn selector to lower FAN setting.
Sound of fan hitting water-moisture
removal system. This is normal when humidity is high. Close
doors, windows
and registers.
Window
vibration-poor
installation.
Refer to installation
instructions
or check with installer.
Improper
installation. TiPtair conditioner slightly
to the outside to a Ilow water drai nage. Refer
to installation
instructions--check
with
installer.
Unit removing
large quantity
of moisture from humid room. This is normal during excessively
humid days.
11