Avoid Service Checklist - Frigidaire FAA074S7A12 Use & Care Manual

Designer series electronic control
Table of Contents

Advertisement

Avoid Service Checklist
Before calling for service
review this list. it may save you time and expense
This list
includes common occurrences
that are not the result of defective workman-ship
or
materials in this appliance.
OCCURRENCE
SOLUTION
Air conditioner
will not operate.
Air from unit does not feel cold
enough.
Air conditioner
cooling,
but room is
too warm - ice forming
on cooling
coil behind decorative
front.
Air conditioner
cooling, but room is
too warm - NO ice forming
on
cooling
coil behind decorative
front,
Wall plug disconnected.
Push plug firmly into wall outlet.
Plug Current Device Tripped. Press the RESET button.
House fuse blown or circuit breaker tripped. Replace fuse with time delay type or resel circuit breaker.
Control is OFR Turn Control ON and set to desired setting.
Room temperature below 60<F (16°C). Cooling may not occur until room temperature
rises above 60<'F (16C).
Temperature sensing etement touching cold coil, located behind air filter. Straighten away from coil.
Resel to a Lower temperature.
Compressor
shut-off by changing modes. Wait approximately
3 minutes and listen for compressor
to restart
when set in the COOL mode.
Outdoor temperature
below 60<F (16°C). To defrost the coil, set FAN ONLY Mode.
Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY Mode.
Temperature is set too Low for night-time cooling. To defrost the coil, set to FAN ONLY Mode. Then, set Tem-
perature to a Higher setting.
Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.
Temperature is set too High. Set temperature
to a Lower setting.
Air directional louvers positioned improperly.
Position louvers for better air distribution.
Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in front of unit.
Doors, windows, registers, elc. open - cold air escapes. Close doors, windows, registers, etc.
Unit recently turned on in hol room. Allow additional time to remove "stored heat" from walls, ceiling, floor and
furniture.
Air conditioner
turns on and off
rapidly,
Dirty air filter - air restricted. Clean air filter.
Outside temperature
extremely
hot. Set FAN speed to a faster setting to bring air past cooting coils more
frequently.
Noise when unit is cooling.
Air movement sound. This is normal. If too loud, set to a slower FAN setting.
Window vibration - poor installation.
Refer to installation instructions
or check with installer.
Water
dripping
INSIDE
when
unit
is
Improper installation. Tilt air conditioner
slightly to the outside to allow water drainage. Refer to installation
cooling,
instructions
- check with installer.
Water
dripping
OUTSIDE
when
unit
Unit removing large quantity of moisture from humid room. This is normal during excessNely humid days.
is cooling,
Room
Too Cold,
Set temperature too low. Increase set temperature.
if These Solutions
Fail, Call 1-800-444-4944
For Frigidaire
Service.