Filling The Water Heater; Venting - Kenmore 153.332362 Owner's Manual

Hide thumbs Also See for 153.332362:
Table of Contents

Advertisement

Installation
Instructions (cont'd)
Filling the Water
Heater
.,CA ON
I
Never usethiswater beater unless it mcomplntely filled with [
waer. To prts_
ddmageto the t_k, the tenk must betilled I
with water. Water must flow from the hot water faucet"I
beforeturning "ON" gasto the _
heater.
]
For proper venting in certain installations, a larger diameter vent
pipe may be necessary. Due to great variances in installations,
balforeseeable by the manufacturer of the water heater, you must
consult your gas company to aid you in determining the proper
venting for your water heater from the vent tables in the latest edi-
tion of the National Fuel Gas Code ANSI Z223.1, also referred to
as NFPA 54.
To fill the water heater with water:
Close the water heater drain valve by turning the handle to
the right (clockwise). The drain valve is on the lower front of
the water heater.
Open the cold water supply valve to the water heater.
NOTE: The cold water supply valve must be left open
when the water heater is in use.
To insure complete filling of the tank, allow air to exit by
opening the nearest hot water faucet. Allow water to run
until a constant flow is obtained. This will let air out of the
water heater and the piping.
Check all new water piping for leaks.Repairas needed.
Venting
AWARNING
VENT DAMPERS- Any vent dampe_ whether it is operated
thermallyor otherwise must be removedif itsuseinhibits prop-
er draftingoftbe water beaten
Thermally Operated Vent Damper_ Gas-fired water heaters
having thermal efEciency in excess of 80%mayproducea rela-
tively lowflue gastemperature.Suchtemperatures maynot be
high enough to properly open thermally operated vent
dampergThiswouldcausespillage of fluegases andmay cause
carbonmonoxide poisoning.
Ventdampersmust bear evidence of certiEcation as complying
with the latestedition of American NationalStandardANSI
Z21.68 (ANSI Z21.66 & 67, respectively,coverelectrically and
mechanically a ctuatedventdampers_Beforeinstallation of any
ventdamper, c onsult yourlocalSearsService Center or the gas
utilityfor further informatiorL
AWARNING
To insure proper venting of this gas-firedwater heater, the
correct ventpipe diameter must be utilized.Any additions or
deletionsof other gasappliances on a commonvent with this
water heater may adverselyaffectthe operationof the water
heater.Consultthe localSearsServiceCenter or gasutility if
anysuch changes are planned.
Check the venting system for signs of obstruction or deterioration
and replace if needed.
The combustion and ventilation air flow must not be obstructed.
AWARNING
[
Obstructed or deterioratedventsystems maypresenta serious
risk or asph_tion.
Place the draft hood legs in the receiving holes on the top of
the water heater. The legs will snap in the holes to give a tight
fit.
Place the vent pipe over the draft hood. With the vent pipe
in position,
drill a small hole through
both the vent pipe and
draft hood. Secure them together with a sheet metal screw.
DRAFT
HOOD
_
]rENTal I #
SCR_V%_'__
DRAFT
HOOD
VENT TO OUTDOORS
DRAFT H __
OR CHIMNEY
A WARNING
]
The water heater with d raft_-ra_-'h'-ood--_ns_dled
must be properly[
vented to a chimneywhich terminatesoutdoors.Neveropel'-[
ate the water heaterunless it isventedto the outdoors end has[
adequateair supply to avoidrisks of improperoperation, e xplo-
sionor asphyxiation.
AWARNING
The vent pipe from the water
heater must be no less than the
diameter of the draft hood outlet on the water heater,and
_
slope
upward to the ch mney
at east
¼nch
per near
13