• Make certain that this dryer is equipped with the
correct burner for the particular gas in the facility. This
information is found on the rating plate in the door
well. If this information does not agree with the type of
gas available, contact your local Sears store or Sears
Service Center.
• The design of this dryer has been certified by the
American Gas Association for use at altitudes up to
10,000 feet above sea level at the B.T.U. rating indi-
cated on the model/serial number plate. Burner input
adjustments are not required when dryer is operated
up to this level.
• When installed above 10,000 feet, a four percent (4%)
reduction of the burner B.T.U. rating shown on the
model/serial number plate is required for each 1,000
foot increase in elevation. For assistance when
converting to other gas types and/or installing above
10,000 feet elevation contact your local service
company.
• Connect exhaust vent to dryer before gas supply is
connected. (see the "Exhaust requirements" section.)
• Provide a gas supply line of ½ in gas pipe to the
machine location. For lengths over 20 ft, larger tubing
should be used. If local codes permit, use flexible
stainless steel tubing (Design Certified by the
American Gas Association) to connect your dryer to
the gas supply line.
• The gas supply line should be equipped with a shut-off
valve. This valve should be located in the same room
as the dryer and in a location that allows ease of
opening and closing. Do not block access to shut-off
valve.
• Pipe joint compounds that resist the action of L.R gas
must be used. Do not use Teflon tape.
• A W-inch NPT plugged tapping, accessible for test
gauge connection, must be installed immediately
upstream of the gas supply connection to the dryer.
The dryer must be disconnected from the gas supply
piping system during any pressure testing of that
system.
NOTES:
• Do not connect this dryer to any type of gas other than
natural gas, without the appropriate conversion kit.
Conversion of dryer, installation and service must be
performed by a qualified installer, service agency, or
the gas supplier.
• Installation of the gas supply lines, the fuel conversion
kit, if required, and the connection of the gas dryer to
the supply, must only be carried out by a fully qualified
and licensed gas installer. Any change to the burner
must also be made by a qualified installer
The dryer must be properly installedand vented to
achieve maximum drying efficiency. Install the dryer in a
well-ventilated
room where the temperature
is always
above 45°E Also make sure that the dryer is
leveled. If the dryer is not properly installed and vented,
it will not be covered under the warranty.
NOTE: Service calls caused by improper venting will be
paid for by the customer, whether it was a paid installa-
tion or self-installed.
For paid installation, call the
company that installed the vent for adjustment.
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in
death or fire.
WARNING:
To reduce the risk of fire, this dryer
MUST BE EXHAUSTED OUTDOORS.
• Do not exhaust dryer into a chimney, a wall, a ceiling,
or a concealed space of a building.
• The diameter of the heavy metal vent must be 4-inch.
• Do not use an exhaust hood with a magnetic latch.
If using an existing exhaust system, remove lint. Make
sure exhaust hood is not plugged with lint.
• Disconnect vent from the dryer and clean one section
at a time until you reach the exhaust hood.
• Use the hose attachment on your vacuum, or a pole
with a feather duster or rag attached, to clean out lint.
• Be sure the flapper on the outside end of vent moves
freely.
• When cleaning is complete, be sure to follow these
Installation Instructions for final product check.
Clean exhaust vent periodically, depending on use, but
at least every 2 years, or when installing your dryer in a
new location.