Service
and Adjustment
Draft
Hood
Operation
Check draft hood operation by performing a worst case depres-
surization of the building. With all doors and windows closed,
and with all air handling equipment and exhaust fans operating,
such furnaces, clothes dryers, range hoods and bathroom fans, a
match flame should still be drawn into the draft hood of the
water heater with its burner firing. If the flame is not drawn
toward the draft hood, shut off"the water heater and make neces-
sary air supply changes to correct.
Tank (Sediment)
Cleaning
Sediment build-up
on the tank bottom may create varying
amounts of noise, and if left in the tank will cause premature
tank failure. In some water areas, you may not be able to drain
all sediment deposits by simply draining the tank. In these cases
Mag Erad (part no. 23600) can be used to help remove the sedi-
ment deposits. This may be ordered from the Sears Service
Center. For ordering, refer to the "Parts Order List" section.
Burner
Inspection
AWARNING
Flood damage to a water heater may not be readily visible
or immediately detectible. However, over a period of time
a flooded water heater will create dangerous conditions
which can cause DEATH, SERIOUS BODILY INJURY,OR
PROPERTY DAMAGE. Call a Sears Service Technicianor
contractor to replace a flooded water heater. Do not
attempt to repair the unit! It must be replaced!
At least once a year a visual inspection should be made of the
main burner and pilot burner. The drawing is for your reference.
You should check for sooting which is not normal and will
impair proper combustion.
AWARNING
Chemical vapor corrosionof the flue and vent system may
occur if air for combustion containscertain chemicalvapors.
Spray can propellants,cleaningsolvents,refrigerator and air
conditioner refrigerants, swimmingpool chemicals,calcium
and sodium chloride,waxes,bleach, a nd process chemicals are
typicalcompounds w hichare potentially corrosive.
AWARNING
I
Obstructed or deteriorated vent systems maypresenta serious
healthr skor asphyx at on.
AWARNING
I
Be sure the vent piping is properly connected to prevent I
escape of dangerousflue gasseswhich could causedeadly
asphyx at on.
AWARNING
If after inspectionof the vent system you found sootingor
deterioration,somethingiswrong.Call the localgasutility to
correctthe problemand cleanor replace the flue andventing
beforeresum ng operat on efthe water heater.
AWARNING
J
Soot
build-up
indicates
a problem
that requires
correction
I
before further
use. Turn "OFF"
gas to water
heater and leave
"OFF"
until repairs are made,
because failure to correct
the J
cause of the sootingcan result in a fire or explosion causing
DEATH,SEROUS BOD LY NJUR_, O R PROPERTY DAMAGE.
Burner Cleaning
In the event your burner needs cleaning, use the following
instructions:
If inspection of the burner shows that cleaning is required, turn
the gas control knob clockwise ( _
) to the "OFF" position,
depressing slightly.
NOTE: The knob cannot be turned from "PILOT" to "OFF"
unless knob is depressed slightly. DO NOT FORCE.
Loose deposits on or around the burner can be removed by care-
fully using the hose of a vacuum cleaner inserted through the
access door of the water heater. If the burner needs to be removed
fbr additional cleaning, call the Sears Service Center to remove
and clean the burner and correct the problem that required the
burner to be cleaned.