Download Print this page
Exergen D-Series Brochure & Specs
Exergen D-Series Brochure & Specs

Exergen D-Series Brochure & Specs

D-series handheld ir c

Advertisement

Quick Links

D-Series Handheld IR Scanners
Common Surface
Temperature
Measurement Errors
1 Pre-set Emissivity errors?
2 Emissivity shift errors?
3 User adjustment errors?
4 Background reflection errors?
5 Contact errors?
6 Friction heating errors?
7 Heat sinking errors?
8 Time based errors?
51 Water Street, Watertown, MA 02172 USA
800-422-3006 • 617-923-9900 • Fax 617-923-9911
Microscanner
D-Series
The Only Certified Accurate
Surface Temperature Instruments
in the World
D501 and D501-RS
Conventional IR
"Point and Shoot"
Microscanner
guns and probes,
D-Series IR
including laser
Thermometers
aimed units
no effect
very sensitive
no effect
very sensitive
no effect
very sensitive
no effect
very sensitive
no effect
no effect
no effect
no effect
no effect
no effect
no effect
no effect
51 Water Street, Watertown, MA 02172 USA
800-422-3006 • 617-923-9900 • Fax 617-923-9911
Conventional
contact probes,
thermocouples,
RTDs,
thermistors
no effect
no effect
no effect
no effect
very sensitive
very sensitive
very sensitive
very sensitive

Advertisement

loading
Need help?

Need help?

Do you have a question about the D-Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Exergen D-Series

  • Page 1 D-Series Handheld IR Scanners Common Surface Measurement Errors 1 Pre-set Emissivity errors? 2 Emissivity shift errors? 3 User adjustment errors? 4 Background reflection errors? 5 Contact errors? 6 Friction heating errors? 7 Heat sinking errors? 8 Time based errors? 51 Water Street, Watertown, MA 02172 USA 800-422-3006 •...
  • Page 2 D-Series Handheld IR Scanners The D-Series is an entirely different type of instrument than conventional temperature measuring devices. Designed specifically for the highest possible accuracy, it is the only infrared instrument which can be certified as to NIST-tracable accuracy on real surfaces of unknown emissivity, while completely free of contact errors and heat sinking errors of contact devices.
  • Page 3 Target T (F) Conventional Infrared D-Series Ambient T (F) Figure 3. D-Series remains accurate even if the ambient temperature varies, while conventional IR devices have considerable inaccuracies. Time Comparison Between D-Series and Contact Thermocouple for Measuring a 500 F (260 C) Surface...
  • Page 4 Air Flow The Infrared Psychrometry method with the D- Series is a direct application of the thermodynamics and mathematics that defines humidity: the D-Series is capable of measuring the true wet-bulb tempera- ture accurately, and with the dry-bulb temperature, the RH can be computed to a very high accuracy via standard psychrometric equations.
  • Page 5 IRt/c sensors require no power and connect directly to standard thermocouple devices available worldwide. Over 300 models offered, covering temperature ranges from -50 to 5000F (-45 to 2760C) with up to 0.01C precision. For more information and pricing, please request a free copy of The IRt/c Book catalog from your local distributor, or Exergen. Microscanner E-Series Microscanner E-Series and IR.1Probe for Electrical Inspection...
  • Page 6 *Optional Analog Output - Specify “AO” example: Microscanner D501-AO **Remote Sensor - Specify Model “RS” example: Microscanner D501-RS 51 Water Street, Watertown, MA 02172 USA 800-422-3006 • 617-923-9900 • Fax 617-923-9911 D-Series Handheld IR Scanners Specifications D1201 D1601 186 - 1207F 186 - 1600F &...

This manual is also suitable for:

D501D501-rs