Theoverfill p rotector ( inthefrontrightcor-
nerof thedishwasher tub)keeps thedish-
washer f romoverfilling. It mustbein place
forthedishwasher to operate,
Checkunder thefloatforobjects thatmay
keeptheprotector frommoving upor down,
Thefiltersystem requires periodic cleaning
as needed, T oclean screen:
1. Unload andslidethebottom rackfor-
ward,(Remove b ottom rackif necessary
toreachfilterscreen,)
2. Remove collected particles fromthe
screen withyourfingers or papertowel,
3. Return thebottom rackto original p osition,
Moving
or winterizing
your
dishwasher
Protect your dishwasher and home against
water damage clue to freezing water lines, If
your dishwasher
is left in a seasonal dwell-
ing or could be exposed to near freezing
temperatures,
have a qualified person do
the following:
1. Disconnect power or unplug dishwasher,
2. Turn off water supply to the dishwasher,
3. Remove the 4 screws on the lower access
panel and remove the lower access panel,