Bag Housing/Dirt Finder Circuitry - Hoover Dimension Service Instructions Manual

Table of Contents

Advertisement

Fig. 3
Fig. 4 t/
/
f
4. Remove
outer bag.
Note: Re-assemble
in reverse
order.
The retention/guide
ribs on the jacket
support
lower must mate with the retention/guide
ribs on
the lower handle.
(Fig. 5A).
Fig. $A
Note: Units without bag door skip to Section
D.
B. Bag housing
(Legacy
II and Dimension)
Bag housinglDirt
Finder
circuitry
(Dirt Finder)
t.
Remove
bag door.
a. Pull bag door latch forward and remove door
from cleaner
(Fig. 5B).
UEO_CY II
DiMENS,_N
Fig. 5B
2. Remove throw-away
bag,
3, Remove
bag housing.
a. Release
two tabs on inside of bag housing
located above dirt tube (Fig. 5C)
/
J
Fig. 6C
Note: On Dimension/Dirt
Finder models, the tool
door and holder must be removed to access the
tabs.
To remove tool door/tool holder.
1. Unsnap hinges at base of door (where
applicable to remove (Fig. 5D).
Fig. 5D
2. Remove
tool holder
mounting screw (located
in
screw cavity
under the dusting
brush).
3. Pry outward on both sides of the tool holder to
release
tabs and pivot holder out of position
(Fig.
5E).