Haier HWR08XC3T User Manual
Haier HWR08XC3T User Manual

Haier HWR08XC3T User Manual

Electronic control
Hide thumbs Also See for HWR08XC3T:

Advertisement

Haier
What
The
World
Comes
Home
To '_
ReomAirConditioner
I:lectronic Control
Read instructions before installing.
Call 1-877-337-3639 for questionson parts and services
00]0546532

Advertisement

Table of Contents
loading

Summary of Contents for Haier HWR08XC3T

  • Page 1 Haier What World Comes Home To '_ ReomAirConditioner I:lectronic Control Read instructions before installing. Call 1-877-337-3639 for questionson parts and services 00]0546532...
  • Page 2: Product Registration

    Thank You for buying a dependable, energy saving and easy to operate HALERroom air conditioner. This manual contains useful information for you to maintain, operate, install and safely use your room air conditioner. Your air conditioner cleans, cools and dehumidifies the air in your room to provide you with the ultimate level of comfort.
  • Page 3: Safety Precautions

    SAFETY P RECAUTIONS WARNING: Following these basic precautions will reduce the risk of fire, electrical shock, injury or death when using your air conditioner. 1) Air conditioner must be connected to proper electrical outlet with the correct electrical supply. (see table) 2) Proper grounding mustbe ensured to reduce the risk of shock and fire.
  • Page 4 PAGE A Word From Haler Product Registration Safety Precautions Warnings Electrical Safety Tips Energy Saving Guide Features Operating Guide 8-14 Normal Operating Sounds Operating Instructions 8=14 Installations 15=24 Parts Tools Installing Unit intoA Window 18=25 Clean and Care Guide 26-27 Troubleshooting 27-28 Warranty...
  • Page 5 Following the safety messages is very important. These messagescan save you from being injured or killed. Warning symbols alert you to be careful and means Danger. Always follow instructions to be safe and reduce chances of injury or death, Warning and Danger signs will precede safety messages.
  • Page 6 • AirConditioners aredesigned foruse ina double hung w indow o r through the wall i nstallation only. (As applicable inyour m odel) • While installing unit b esure totiltairconditioner _/4 inch outward to have t he water drip outside the house. _•...
  • Page 7 side vent eledronic touch pad slide-out easy-access chassis filters (All featuresnot on all models) 1. Thermostat cold air for your comfort. b) Dehumid. This allows you b adjust the temperature of the air. The lower the setting the cooler the air temperature. This enables your air conditioner to operate as a dehumidifier as well.
  • Page 8 6. Vent (not in all models) 10. Remote Control This feature helps you to exhaust any stole This fell functionalwireless remote allows you to unwanted air kom the room and draw fresh outside operate your air conditioner From a dis_nce air in the room.
  • Page 9: Operating Sounds

    Normal Operating Sounds The following sounds are normally heard during the operation of an air conditioner. Cool • airflow movement as dictated by the set [an speed. • Water sounds. This is normal as your air conditioner acts as a dehumidifier also, Thus you will hear water sounds from water drops falling on the condenser.
  • Page 10 After you plug in the unit it will perform a self test. All the display lights will turn on for 3 seconds. The LED display will read "88". If any display light fails to turn on you may need service on the unit. After the 3 seconds self test the unit will automatically go to the stand by mode.
  • Page 11 Fig. # 3 Control Panel. Once the Functionmode is decided you will have to set the fan speed. If you choose the A/C mode you can run the fan in one of the 3 speedsHi, Med., Lo or in the Auto speed. In the Auto speed the fan will start at High, Meal or Lo as the temperature varies in the room.
  • Page 12 If you choose to use the Dehumid function. This will remove excess moisture from the air on excessively humid days. Tr: temperature inside the room. Ts:the set temperature. 1) When Tr>Ts÷3°F, t he compressor will run continuously the fan at the selected speed.
  • Page 13 Timer start or Timer stop mode is used to pre-start or shut off your unit in advance. You can program this up to 12 hours in advance. You can use the Timer in 3 functions i.e. A/C, Dehumid. or Fan Only. •...
  • Page 14 Sleep lets you preset the unit to shut off in 8 hours. Sleep works in the A/C function only. After pre-setting the temperature to a set degree, the temperature raises by 2 degree in the 1st hour and another 2 degree in the 2nd hour and then remains constant in the next 6 hours.
  • Page 15 Fig. # 9 Control Panel i ¸ _ii_i ......... When unitis in "On" mode the LEDdisplay will show room temperature. Pressthe (+) key to get set temperature. When unit is in "Timer Stop" func- tion, LEDdisplay will show the time left for the unit to shut off. To cancel Timer Stop pressthe main Off key.
  • Page 16 Before you install your air conditioner check the following: 1) The unit is free of all obstructions inside and outside the room e.g. drapes, curtains, furniture, plants, shrubs, bushes, trees, other structures like building, garage etc. Air conditioner must have clear unobstructed airflow through the condenser to remove the heat.
  • Page 17 Parts Par_s Supplied basep "CR2025" battery RemoJ¢ contro curtain sash window seal curtain screws attachmenl gaskel 31/32" screws 13/32 _' Model: HWROSXC3-T cuff an sash screws Casemen curtain 3//32" window affachment securance screw I" &_ screws 13/32 "CR2025" _attery left and right Remote side curtains control...
  • Page 18 Tooms tools You will need to have the following to help you in the installation of your air conditioner. *Scissors *PhillipsScrewdriver *Standard Screwdriver *Pliers eWrench "Drill and Drill Bits .Tape Measure *Gloves • Level •Sockets...
  • Page 19: Installing Unit Into A Window

    Installing Unit into A Window Window Opening Requirements The air conditioner is designed to fit into double or single hung sash type windows. Each of he units comes with an installation kit that provides adjustable mounting louvers, to fill the gaps between the sides of the unit, and the window frame.
  • Page 20 PREPARE Storm window installation Mobile home window installation I sorm wndow frame does not allow Add wood strip (a_ least 1 /2" wide} WINDOW adeauate clearance below sill /2" dang entre wldh of window INSTALLATION _eq_U_d), remove star rl window Th ekness of wood strip should mmch Ins_oecl window track, sash, and sll frame o create clearer ce by adding...
  • Page 21 INSTALLSEAL GASKET efficiency. Models HWRIOXC3-T HWRI 2XC3-T PREPARE UNIT INSTALLATION Unpack unit on floor next to installation location, Remove front attachment screw Separate _he outercase from the front with a putty knife atthe catch paints designated by the arrows. Remove one screw securing basepan locking bracket, Remove two screws located in the rear of the outercase, securing basepan to...
  • Page 22 ASSEMBLE CURTAINS/TOP RAIL Install lop rail wiih ihree _3/32"scraws Slide left-hand curtain assembly in-o left end of top and bottom rails Repeat for righ-hand cur:ain assembly. Fasten cur aln retainer strps to sides of outer case witft six 13/32' screws Storm window installation...
  • Page 23 INSTALL OUTER CASE IN WINDOW Place ouer case in window_ Lower sasl untl i_ _esls behind front flange of _op rail. Boitom _all musi _os behnd window slL Expand bah curia ns o coniac[ Ihe wndaw flame. InsJall twa 31/32' awat' fo_ cladv saews.
  • Page 24 INSTALLSEALGASKET Cut window seal gasket to width of window. Stuff window seal strip belween outdoor window glass and top of indoor sash. This will stop air leakage which reduces efficiency. IMPORTANT: Stay clear of glass, Be careful not to damage the function of the window.
  • Page 25 Wall Installations: slide-out chassis only Note: Remove the 1 or 2 shipping screws on the rear of the air conditioner that hold the chassis to the outer shell casing. Once removed, these do not have to be re-installed. To ensure that your air conditioner is properly installed in the wall, it is recommended that it be installed by a certified technician who is familiar with through the wall installations.
  • Page 26: Tips

    wall_ Fig. # 20 typical casing outward tip casing 4) The casing should be tilted 1/4" outside so as to drain the excess dehumidified water. 5) Properlyinsulate any opening betweenthe casing and the frame. 6) Using the screw holeson the sides of the unit, which are for the window mounting kit and the screwholes in the top mounting kit rail, attach the casing to the wood Frame.
  • Page 27 lop-air IouveYs side-a_r louvers fig. # 21 fig. # 22 • Always unplug your air conditioner before cleaning. • Air filter needs to be cleaned at least once a mouth for your unit to operate at optimum efficiency. The filter can be slid out from the side by pulling on the tab located on the middle right side of the front mask.
  • Page 28 To store your air conditioner, after the season, remove the unit from the window as per the installation guide. Repack the unit in its original box and store away. If your unit is installedin a wall or you do not intendto remove it from the window then cover the outside with a winter cover.
  • Page 29: Operating Guide

    Air conditioner working but room not cooling: • Room may have appliances that produce heat. Use an exhaust fan to remove excess heat. • Redirect the airflow. Removeany obstacles. • All doors and windows need to be closed so cool air does not escape the room.
  • Page 30: Parts

    12 month period. the date of purchase. THIS LIMITEDWARRANTY IS GIVEN Who is covered? IN LIEUOF ALL OTHERWARRANTIES, EXPRESS OR The original retail purchaser of this Haier product. IMPLIED,INCLUDING THE WARRANTIESOF MERCHANTABILITYAND FITNESSFOR A What will be done? PARTICULAR PURPOSE.
  • Page 31 DATED PROOF OF PURCHASE REQUIRED FOR WARRANTY SERVICE FOR SPECIFIC ELECTRICAL RATING, REFER TO ELECTRICAL RATING NAMEPLATE ON YOUR UNIT Made in China Haier What The World Comes Home To N Haler America York, NY 10018 Printed in China eca/c-03...

Table of Contents