Troubleshooting Guide - Aficionado C883 User Manual

Hide thumbs Also See for Aficionado C883:
Table of Contents

Advertisement

13.Troubleshooting
Guide
PROBLEM
POSSIBLE
CAUSE
POSSIBLE
SOLUTION
Ice maker is unplugged
Plug ice maker in.
Reset breaker - if it happens again, call an authorized service
Breaker tripped
center.
Switch turned to "OFF"
Turn switch to "ICE".
Level of ice has reached sensor tube - it is normal for ice maker to
Ice maker does not
Storage bin is full, keeping ice
be off.
operate
maker off
Ice maker in a room below 50°F(10°C) - room must be warmer for
ice maker to operate.
Drain pipe blocked
Clean the interior of drain pipe.
(Drain pump model)
Drain pump not operative
Check the drain pump.
(Drain pump model)
Call an authorized service center.
Ice cubes are too large
Cube size control is set too cold
Call an authorized service center.
Check water supply - filter may be restricted.
Not enough water
Ice cubes are too small
Check inlet water valve - inlet screen may be restricted.
Cube size control set too warm
Call an authorized service center.
Ice cubes are partially
Spray jets may be partially
formed - ragged sides
clogged
Activate wash cycle (See page 19).
Storage bin should fill with ice
and ice maker should shut off in
Clean condenser.
12~16 hours -if not, condenser
Ice maker makes ice,
may be dirty
but storage bin does
Storage bin drain may be
not fill with ice
Clean out drain, check installation.
partially restricted
Air flow to ice maker may be
Check installation - kick plate/grill must be free of obstructions.
obstructed
Ice cubes are partially
Check water supply - filter may be restricted.
formed - white at the
Not enough water in reservoir
Check inlet water valve - inlet screen may be restricted.
bottom
Check for water leak in reservoir.
Check water supply - filter may be restricted.
Ice may be stuck in the
Check inlet water valve - inlet screen may be restricted or valve
evaporator
and the unit is "frozen
up"
does not operate.
Hot gas valve may not operate - check and repair or replace.
Too much heat load
Inlet water valve leaks through, must be replaced.
Water pump does not operate, must be replaced or check for water
No water spray
leak in reservoir.
Unit operates but no
ice falling into storage
Fan motor does not operate or fan blade is broken, must be
bin
No airflow
replaced.
Condenser is completely
blocked, must be cleaned.
Compressor
does not operate
Call an authorized service center.
properly or at all
Not enough refrigerant
Call an authorized service center.
Hot gas valve leaks through
Call an authorized service center.
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

C887

Table of Contents