ELECTRICAL
CONNECTION
INFORMATION
CAUTIONs
FOR PERSONAL
SAFETY:
DO NOT USE AN EXTENSION CORD OR AN ADAPTER
PLUG WiTH THIS APPLIANCE,
DO NOT, UNDER ANY C_RCUMSTANCES, CUT OR
REMOVE THE THIRD GROUNDING PRONG FROM THE
POWER CORD,
Dryer must be e_ectficaHy grounded in accordance with
local codes and ordinances, or in the absence of local
codes, in accordance with the NATIONAL ELECTRICAL
CODE, ANSI/NFPA NO. 70-1990
The electrical diagram is located inside control panel
Electrical requirements
. This appliance must be supplied with !20V, 60 Hz, and
connected to an individual, properly grounded branch cir-
cuit, protected by a 15 or 20 amp circuit breaker or time-
delay fuse.
If the electric supply provided
does not meet the above specifi-
cations, it is recommended that a
licensed electrician install an
approved outlet
External
ground (if required)
An external ground wire, (not pro m
INSURE
PROPER
GROUND
EXISTS
BEFORE
USE
vided), which meets local codes, REAR VIEW
may be added by attaching to the
];I
"\_.
_ LI
green ground screw on the rear
]//
"--._.._t__}
of the dryer, and to grounded
metal cold water pipe or other
established ground.
AT3['ACH GROUND
W_E
TO
_AON ORY£R
(OBTAIN
LOCALLY}
GAS CONNECTION
INFORMATION
Installation must conform with local codes and ordi-
nances, or in their absence the NATIONAL FUEL GAS
CODE, ANSi 2223 1-1988
GAS BURNER
ORIFICE
This gas dryer is equipped with a Valve & Burner
Assembly for use on{y with natural gas. Using a separate
conversion kit your local Service organization can convert
this dryer for use with gases listed on the rating piate.
ALL CONVERSIONS
MUST BE MADE BY PROPERLY
TRAINED AND QUALIFIED
PERSONNEL, AND iN
ACCORDANCE
WITH LOCAL CODE AND ORDINANCE
REQUIREMENTS.
GAS SUPPLY
• Supply line is to be 1/2" rigid pipe, (3/4" copper tubing
may be used if the dryer is operated on Liquefied
Petroleum gas), and equipped with an accessible shut-
off within 6 feet of, and in the same room with the dryer
increase pipe size for runs longer than 20 feet,
• Protection of Dryer During Pressure Test:
- When test pressure is in excess of 1/2 PSiG
(3,45kPa), disconnect dryer and its individual shutoff
valve from gas supply line prior to test
- When test pressure is equal to or less than 1/2 PSIG
(3,45kPa), close the dryer shutoff valve prior to test
• A 1/8_'National Pipe Taper thread plugged tapping,
accessible for test gauge connection, must be installed
immediately upstream of the gas supply connection to
the dryer, Contact your tocal gas utility should you have
questions on the installation of the plugged tapping.
- Pipe dope must be resistant to the action of L P. gases
and applied sparingly to all male threads
• If tocal codes permit, it is recommended
the dryer be
connected to the gas supply with approved semi-rigid
metal tubing or listed connectors_
LEAK TEST
Check all connections for leaks with soapy solution or
equivalent. Leak test solutions must not contain ammonia
which could cause damage to brass fittings or pipe, CAU_
TION: NEVER USE AN OPEN FLAME TO TEST FOR
GAS LEAKS
GAS SUPPLY LOCATION
Note: Units have separate gas suppiies
2 5/8_J
1
t
©
\
_/a"MALE THREAD
GAS SUPPLY