Selecting A Mounting locAtion
1. Give consideration to the weight of the unit when operating (filled with water). Operating weights
of the Insurice Systems are:
• Single System - 9 lbs. (4.0 kg.)
• Twin System - 19 lbs. (8.5 kg)
• Triple System - 27 lbs. (12 kg)
• Quad System - 36 lbs. (20 kg)
2. The location should allow for:
• M inimum clearance of 2-1/2" under the cartridge(s) so it can be lowered for removal and re-
placement.
• Adequate space for "in" and "out" water line connections.
• B e near a drain for flushing and near a 110V outlet if the accessory (sold separately) Everguard
Low Pressure Alarm is used. See Figures 1-4.
3. I f possible, keep at least 6" available to the left and the right of the Insurice System in the event
poor quality water conditions require the installation of the optional Everpure K-Series Prefilter.

operAting SpecificAtionS*

combined Model name
Insurice Single - i2000
Insurice Single - i2000
2
Insurice Single - i4000
Insurice Single - i4000
2
Insurice Twin - i2000
Insurice Twin - i2000
2
Insurice Twin - i4000
Insurice Twin - i4000
2
Insurice Triple - i2000
Insurice Triple - i2000
2
Insurice Triple - i4000
Insurice Triple - i4000
2
Insurice Quad - i2000
Insurice Quad - i2000
2
Insurice Quad - i4000
Insurice Quad - i4000
2
* For individual cartridge specifications, refer to cartridge literature.
temperature: 35-100°F (2-38°C)
pressure:
10 - 125 psi (0.7 - 8.6 bar), non-shock
For cold water use only.
Manufactured by Everpure
replacement
flow rate
cartridge
i2000
1.67 gpm (6.3 lpm)
i2000
1.67 gpm (6.3 lpm)
2
i4000
1.67 gpm (6.3 lpm)
i4000
1.67 gpm (6.3 lpm)
2
i2000
3.3 gpm (12.6 lpm)
i2000
2
3.3 gpm (12.6 lpm)
i4000
3.3 gpm (12.6 lpm)
i4000
3.3 gpm (12.6 lpm)
2
i2000
5.0 gpm (18.9 lpm)
i2000
5.0 gpm (18.9 lpm)
2
i4000
5.0 gpm (18.9 lpm)
i4000
5.0 gpm (18.9 lpm)
2
i2000
6.6 gpm (25 lpm)
i2000
2
6.6 gpm (25 lpm)
i4000
6.6 gpm (25 lpm)
i4000
6.6 gpm (25 lpm)
2
Installation and Operation Guide
capacity
9,000 gal (34,000 L)
9,000 gal (34,000 L)
12,000 gal (45,420 L)
12,000 gal (45,420 L)
18,000 gal (68,000 L)
18,000 gal (68,000 L)
24,000 gal (90,840 L)
24,000 gal (90,840 L)
27,000 gal (102,000 L)
27,000 gal (102,000 L)
36,000 gal (136,260 L)
36,000 gal (136,260 L)
36,000 gal (136,260 L)
36,000 gal (136,260 L)
48,000 gal (181,680 L)
48,000 gal (181,680 L)
Insurice Filter Systems
Figure 1 – Insurice Single System
Figure 2 – Insurice Twin System
Figure 3 – Insurice Triple System
Figure 4 – Insurice Quad System
EV3112-81 Rev E AP08

Advertisement

loading
Need help?

Need help?

Do you have a question about the Insurice Filter Systems EV3112-81 and is the answer not in the manual?

Questions and answers

Summary of Contents for Everpure Insurice Filter Systems EV3112-81

  • Page 1: Operating Specifications

    • Single System - 9 lbs. (4.0 kg.) • Twin System - 19 lbs. (8.5 kg) • Triple System - 27 lbs. (12 kg) • Quad System - 36 lbs. (20 kg) 2. The location should allow for: • M inimum clearance of 2-1/2” under the cartridge(s) so it can be lowered for removal and re- placement. • Adequate space for “in” and “out” water line connections. • B e near a drain for flushing and near a 110V outlet if the accessory (sold separately) Everguard Low Pressure Alarm is used. See Figures 1-4. 3. I f possible, keep at least 6” available to the left and the right of the Insurice System in the event poor quality water conditions require the installation of the optional Everpure K-Series Prefilter. operAting SpecificAtionS* replacement combined Model name cartridge Insurice Single - i2000 i2000 Insurice Single - i2000 i2000 Insurice Single - i4000 i4000...
  • Page 2 6. I nstall the cartridge(s) into the Insurice system head(s) following directions on the cartridge label or as shown in the Cartridge Change illustrations. 7. Turn on water to filter and check for leaks. 8. F lush the cartridge by running water through at full force for five minutes. This will set the filtering media and purge air and fines, insuring maximum filter life. 9. A fter flushing, close the flushing valve, turn on power to equipment and plug the LPA (if so equipped) into the electrical outlet. See illustrations. cArtridge chAnge deterMinAtion Replace cartridges when capacity is reached, or when flow becomes inadequate, but at least annually. All cartridges on multiple cartridge systems should be changed at the same time. The Everpure Pressure Gauge or Everguard Low Pressure Alarm provides a quick and simple means of determining when the filter cartridge(s) should be changed. Installed on the outlet port of the filter, the gauge or Everguard LPA can be used to measure both dynamic (flowing) and static (line) pressure. The cartridge(s) should be changed when the pressure gauge needle is in the red area while equipment is in operation, and yet the needle shows adequate line pressure between cycles. Observe the needle during the next equipment on cycle. If the needle registers adequate pressure, it can be assumed that the temporary low-pressure condition was caused by a brief power failure or other incoming pressure disruption. fluShing for maximum life, all carbon filter cartridges must be flushed for five minutes at full flow before use. All...
  • Page 3: Replacement Parts

    Outlet pressure gauge Inlet pressure gauge (quad only) Inlet valve (twin, triple & quad) Flushing valve preSSure gAugeS Low Inlet Pressure cArtridge chAnge procedure everpure carbon filter cartridge 2. O pen flushing valve to relieve change pressure. 1. S hut off power to equipment. Shut 3. H old head firmly and push upward. off inlet water ahead of system. Turn cartridge to left until it stops. for installations in Massachusetts, the commonwealth of Massachusetts plumbing code 248 cMr shall be adhered to. consult your licensed plumber for installation of the system.
  • Page 4: Limited Warranty

    Any part found defective within the terms of this warranty will be repaired or replaced (at everpure’s discretion) by your local dealer or everpure technical service. you pay only freight from our factory and local dealer charges.

This manual is also suitable for:

Insurice quad i2000Insurice single i20002Insurice twin i20002Insurice triple i20002Insurice quad i20002Insurice quad i4000 ... Show all