Cabinet Dimensions - KitchenAid KECC501BAL0 Installation Instructions Manual

30" and 36" electric built-in ceramic cooktops
Hide thumbs Also See for KECC501BAL0:

Advertisement

Available languages

Available languages

Product dimensions
t4-i:::
IRS xrnj Zdth _I
---
height
t
Cabinet dimensions
* Note: 24" (61 cm) min.
clearance
If bottom of
wood or metal cabinet
is protected
by not
less than l/4" (0.6 cm)
flame retardant
millboard
covered
with
not less than No. 28
MSG sheet steel,
0.015" (0.04 cm)
stainless
steel, or
36" (91.4 cm) or 30" (76.2 cm) min. base
cabinet
is required. If cabinet has a drawer,
a 3" (7.5 cm) depth clearance from the
countertop to the top of the drawer (or other
obstruction)
in the base cabinet is required.
0.024"(0.06
cm)
4
width above'cooktop
aluminum
or 0.020"
(0.05 cm) copper.
30" (76.2 cm) min.
clearance
between
top
of cooking
platform
and bottom of
For minimum
L-
unprotected
wood or
clearances,
13" (33 cm) - _ '
see Note.*
aper -4
max. ul
cabinet
depth
18" (45.7 cm)
min. clearance
upper cabinet
to countertop
Do Not seal
cooktoo
to
25" (63.5 cm)
countertop
depth
24" 161 cm)
lower cabinet
depth
cm) min.
Cutout dimensions
30" (76.2 cm) Cooktop
4
26-112" (75 cm)
*
opening
width
4
\7-l,2"~~~~~e%$~e
and rear combustible
surface
above
countertop
36" (91.4 cm) Cooktop
4
35-l/2"
(90.2 cm)
opening
width
Before you start...
Proper installation
is your responsibility.
Make sure you have everything for correct
installation.
It is the responsibility
of the
installer to comply with the installation
clearances specified on the serial/rating
plate. The serial/rating
plate is found on the
bottom of the cooktop.
Cooktop installed over oven installation:
Cooktop models KECC501 B, KECC502B,
KECC507B, KECC560B, KECC567B, can
be installed over oven models KEBNl OOY
and KEBNlO7Y.
Check location
where cook-top will be
installed. The location should be away from
strong draft areas, such as windows, doors
and strong heating vents or fans. The
cooktop should be located for convenient
use in the kitchen.
Grounded electrical supply
is required.
See "Electrical requirements."
Important:
Observe all governing codes and
ordinances.
Failure to meet governing codes and
ordinances could lead to fire or electrical
shock.
Countertop opening dimensions
that are
shown must be used. Given dimensions
are
minimum clearances and provide required
0" (0 cm) clearance.
New installations
-follow
minimum
dimensions
given.
Replacement installations
-
Be sure that
front edge of cook-top is at least l-112"
(3.8 cm) back from front edge of countertop.
A built-under oven may be installed under
this cooktop if oven is approved for this type
of installation.
Check for approval label
located on top of oven. If label is not
located, contact dealer to confirm that oven
is approved. Refer to oven manufacturers
Installation
Instructions for approval and
proper cutout dimensions.
When installing cooktop over a built-
under oven,
Do Not fasten cooktop to
countertop with clamps. Cooktop then will
be easy to remove if servicing is ever
necessary.
ALL OPENINGS
IN THE WALL OR FLOOR
WHERE THE COOKTOP IS TO BE
INSTALLED MUST BE SEALED.
Electrical Shock Hazard
lt is the customer's responsibility:
l
To contact a qualified electrical
installer.
l
To assure that the electrical
installation
is adequate and in
conformance with National Electrical
Code, ANSUNFPA 70 - latest
edition**, or Canadian Electrical
Code, C22.1 - 1982 and C22.2 No.
01982 (or latest edition)*'* and all
local codes and ordinances.
Failure to do so could result in
electrical shock or other personal
injury.
Personal Injury Hazard
To eliminate the risk of burns or fire,
avoid installing cabinet storage above
the cooking surface. If cabinets are
already installed, reduce the hazard of
reaching over a heated cooking
surface by installing a range hood.
The range hood should extend a
minimum of 5 inches (12.7 cm) out
from the bottom of the cabinets.
Reaching over a heated cooking
surface could result in a serious burn.
Copies of the standards listed may be obtained from:
l
* National
Fire Protection
Association
Batterymarch
Park
Quincy,
Massachusetts
02269
l
*" Canadian
Standard
Association
178 Rexdale
Boulevard
Rexdale,
(Toronto
), Ontario
M9W 1 R3
A
\7-l12"~~~~~e;~~
and rear combustible
surface
above
countertop
Panel A