Specifications; Service Kits; Technical Data - Parker WCS-SIF-01 Training & Maintenance Manual

Pneumatic spotwelding control systems
Table of Contents

Advertisement

WCS-SIF-01

Specifications

Pneumatic System
with Low Impact and
Rapid Approach Control
Description
Pneumatic valve block for use with pneumatic weld
gun cylinders. The block has an integrated low impact
system and is provided with two solenoid operated
"Namur" or ISO size  valves. One valve for the retract
(pre-stroke) and one for the weld stroke. The valves
can be of the single solenoid type or the double
solenoid type. The block is available for different
constructions of cylinders:
DH / WH = 3 Ported Cylinders
DP / WP =  and 4 Ported Cylinders
Ordering Code:
See pages 7 – 13.
Dimensions:
See pages 15 – 18.
Applications
The Spotwelding System can be used with any
Pneumatic Spot Weld Cylinder.
Mounting
The weld block can either be mounted on the side of
the robot or directly to the cylinder. See pages 10 – 1
for bolt hole patterns for robot mount. Consult Parker
for cylinder mount application.
Pneumatic
Training & Maintenance Manual

Technical Data

Medium .......................... Compressed air, filtered to
Working Pressure ..........37 to 145 PSIG (.5 to 10 bar)
WH Series Air Operated
Quick Exhaust ..........40 to 115 PSIG (.7 to 7.9 bar)
Ambient Temperature ...... 41°F to 10°F (5°C to 49°C)
Weight –
DP ................................................. 1.0 lbs (5.4 kgs)
DH ................................................... 7.0 lbs (3. kgs)
WP (with Baseplate) ...................... 14.0 lbs (6.4 kgs)
WH (with Baseplate) ...................... 18.0 lbs (8. kgs)
Pneumatic Valve
4 VDC
Operating Voltage Solenoids .... 4 VDC +10/-15%
Power Consumption .....................................4.8W
Class of Protection ....................... IP65 (with plug
Connector ............................ M1, mm, 30mm,
10 VAC
Operating Voltage Solenoids ...10 VAC +10/-15%
Frequency ............................................50 / 60 Hz
Power Consumption ..................... 7.8 VA / 6.3 VA
Class of Protection ....................... IP65 (with plug
Connector ............................ M1, mm, 30mm,
Proximity Sensor
4 VDC
Supply Voltage ................................10 to 30 VDC
Rated Operational Current ........................00mA
Degree of Protection .....................................IP67
Ambient Temperature Range ....... -13°F to 158°F
Switching Indication ................... By LED (Yellow)
Output ..............................................PNP or NPN
10 VDC (Consult factory for availability)
Supply Voltage .............................. 0 to 140 VAC
Frequency ......................................... 50 or 60 Hz
Supply Voltage Indication ........... By LED (Green)
Rated Operational Current .......................400 mA
Degree of Protection .....................................IP67
Ambient Temperature Range ...... -13°F to 158°F
Switching Indication ................. By LED (Orange)

Service Kits:

See page 9.
6
40µ and dried to a dewpoint
of 37°F (3°C), lubricated
or non-lubricated. Once
lubricated air is applied, this
must be maintained.
mounted)
Auto (ISO  only)
mounted)
Auto (WP / WH only)
(-5°C to 70°C)
(-5°C - +70°C)
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics