Unless otherwise specified, all products presented in this user's guide are warranted against defects in material and workmanship for a period of one year from the date of invoice by PANDUIT® Corp. to the initial purchaser. During the warranty period PANDUIT Corp. will, at its discretion, either repair or replace products that prove to be defective.
Page 3
E™ Power System User Manual Part Number: PN380C The remedies provided herein are Buyer's sole and exclusive remedies. PANDUIT Corp. shall not be liable for any direct, indirect, special, incidental or consequential damages, whether based on contract, tort or other legal theory.
E™ Power over Ethernet Systems may be powered individually using a DP E™ Power Supply (PANDUIT part # DPOEPWRB120Y), which delivers 120 watts at 48 Volts of Direct Current (VDC) to a single DP E™ Power Patch Panel or DP E™...
For connection and mounting torque requirements see Table 6: Recommended Torque Settings. PANDUIT Corp. does not recommend shipping the chassis with the rectifiers installed. Rectifiers should be shipped in their separate boxes. Package Contents The DP E™...
E™ Power System User Manual Part Number: PN380C Table 2: DP E™ Power Components Available from PANDUIT PANDUIT Part Number Description DPOEPWRB120Y Individual power supply - 120 watt power supply – 48 volt output DPOEPWRCU Unmanaged power chassis (supports 3 rectifiers)
E™ Power System User Manual Part Number: PN380C N+1 DC Out Rectifiers Feed 1 AC In Feed 2 Feed 3 Figure 2: Individual AC Feed Wiring Architecture Each individual AC feed should be protected using a circuit breaker as listed in Table 4: Recommended AC Circuit Breaker and Wire Sizes.
The bulk DC connection may be used as a battery input or as an unfused bulk output. The connections require a terminal lug (1/4” single hole lug with a max tongue width of 0.63” or less), such as PANDUIT part # LCA4-14-L. Size wires based on the total rectifier capacity and choose conductor size according to Table 5: Minimum Recommended DC AWG for 90°C Cabling for Unprotected Outputs...
B-feed power option, but the terminals and wire leads are not attached to the power harness. Contact PANDUIT Technical Support for more information about connecting the redundant B-Feed power. (PANDUIT part # DPOEPWRDUAL should be used for redundant powering options) WARNING: The power supply connections on the DP E™...
E™ Power System, note any physical package damage that could indicate potential damage to the contents. After removing the DP E™ Power System from the boxes and packing material, inspect for shipping and/or other damage. Any problems should be reported to PANDUIT technical support. Table 7: PANDUIT Corp. Contact Information...
1RU shelf (part # SRM19FM1) with a load rating of 30 lbs that will help support the chassis. For optimum saftety, a 2 RU shelf (PANDUIT part # SRM19FM2 – shown below) with a load rating of up to 50 lbs may be installed.
E™ Power System User Manual Part Number: PN380C AC Input Slip the cord bracket around each cord (PANDUIT part # CORD-****), as shown in Figure 7: Cord Bracket. Plug the cord into the proper receptacle on the back of the chassis (See...
(1/4” single hole lug with a max tongue width of 0.63” or less). Terminal lugs (such as PANDUIT part # LCA4-14-L for use with #3 or #4 AWG stranded wire or #2 AWG solid wire) and crimping tools (such as the PANDUIT part #s CT-1550, CT-1551, CT-1570, or CT-1700) are available from PANDUIT Corp.
E™ Power System User Manual Part Number: PN380C TEST AND TURN-ON Once all AC and DC connections have been secured and checked, install each rectifier sequentially by sliding and latching it into the chassis as illustrated in the section below. Rectifiers The rectifiers for use in the DP E™...
E™ Power System User Manual Part Number: PN380C TROUBLESHOOTING The modular nature of this DP E™ Power System makes diagnostics and repair easy. Make sure that all rectifiers are properly seated and latched into their respective slots. Make sure all power and signal connectors are properly mated.