PROBLEM
Cleaner won't start
Vacuum stops
Poor job of dirt pick-
up
Performance indicator
is Red
Cleaner picks up
moveable rugs
Cord won't rewind
Trouble Shooting Guide
POSSIBLE CAUSE
1. Unplugged at wall outlet.
2. Tripped circuit
breaker/blown fuse
1. Motor overheating
1. Full or clogged dust bag.
2. Dirty air input filter.
3. Wrong pile height setting.
4. Open suction control.
5. Hole in hose.
6. Canister hood open.
1. Full or clogged dust bag.
1. Wrong pile height setting.
2. Suction too strong.
1. Dirty power cord.
2. Cord jammed.
POSSIBLE SOLUTION
1. Plug in firmly, push
On/Off switch to On.
2. Reset circuit breaker or
replace fuse.
1. Let vacuum cool off.
2. Change bag.
1. Change bag.
2. Clean filter.
3. Adjust setting.
4. Adjust control.
5. Replace hose.
6. Close and latch hood.
1. Change bag.
1. Adjust setting.
2. Open suction control.
1. Clean power cord with
damp cloth.
2. Pull out cord and rewind.
8