Download Print this page

Craftsman 390.2505 Owner's Manual page 5

Shallow well jet pump

Advertisement

ELECTRICAL
Disconnect
power
before
working
on pump,
motor,
pressure
switch,
or wiring.
Motor
Switch
Settings
If the motor
can operate
at either
115 or 230 volts, it
is set at the factory
to 230 volts. Do not change
motor
voltage
setting
if line voltage
is 230 volts, or if
you have a single voltage
motor.
NOTICE:
Never wire a 115 volt motor to a 230 volt line.
Remove
Motor
End Cover
Figure
4 - Removing
Motor
End Cover
Dial Type Voltage
Selector
Power Supply Connections
You will need to remove
the motor
end cover to
change
the voltage
setting.
The illustration
above
also
shows
the pressure
switch.
If the power
supply
con-
nection
still needs to be made, the pressure
switch
cover will need to be removed.
Your motor
terminal
board
(located
under
the motor
end cover)
should
look like the one at right.
Figure 5 - Voltage
Set To 230 Volts, Dial Type
To change
to
I 15 volts:
1. Make sure power
is off.
2. Turn the dial counter-clockwise
until
115 shows
in
the dial window.
3. Reinstall
the Motor
end cover
4. Go to Wiring
Connections,
Page 6.
[AWARNING I Hazardous
voltage.
Can shock,
burn,
or kill. Connect
ground wire before
connecting
power
supply wires. Use the wire size (including
the ground
wire) specified
in the wiring
chart.
If
possible, connect
the pump to a separate branch cir-
cuit with no other appliances on it.
[AWARNING I Explosion
hazard.
Do not ground
to
a gas supply
line.

Advertisement

loading