Download Print this page
HP Surestore Disk Array 12h - And FC60 Configuration
HP Surestore Disk Array 12h - And FC60 Configuration

HP Surestore Disk Array 12h - And FC60 Configuration

Factory configuration for 1 disk enclosure
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:

Advertisement

A5277AZ Factory Configuration for 1 Disk Enclosure
Recommended FC60 Configuration
Single host, dual-controller disk array, 1 disk enclosure, 5 RAID 1 LUNs
Host
FC Adapter A
FCAL-A
Controller A
FC60 Enclosure
LVD
SCSI
LUN 1
LUN 2
LUN 0
SC10 Disk Enclosure
FC Adapter B
FCAL-B
Controller B
LVD
SCSI
LUN 4
LUN 3
Red and Blue drives are on separate SCSI buses
Hardware Configuration
– FC60 controllers connected directly to host FC adapters
– One disk enclosures with ten 18 GB disk modules in each
– Disk enclosure set to split-bus mode by setting option
switch 1 DOWN on BCCs
– Unused SCSI connectors on FC60 enclosure must be terminated
– Expansion SCSI connector on disk enclosure must be terminated
LUN Configuration
– Five RAID 1 LUNs, comprising 2 disks each (1+1)
– Each disk in the LUN is in a separate enclosure
High Availability
Handles the failure of a single disk, controller, BCC, or SCSI channel
– Does not handle the failure of the disk enclosure
Disk Capacity
Maximum capacity ~180 GB
– Usable capacity ~90 GB

Advertisement

loading

Summary of Contents for HP Surestore Disk Array 12h - And FC60

  • Page 1 A5277AZ Factory Configuration for 1 Disk Enclosure Recommended FC60 Configuration Single host, dual-controller disk array, 1 disk enclosure, 5 RAID 1 LUNs Hardware Configuration – FC60 controllers connected directly to host FC adapters Host – One disk enclosures with ten 18 GB disk modules in each –...
  • Page 2 A5277AZ Factory Configuration for 2 Disk Enclosures Recommended FC60 HA Configuration Single host, dual-controller disk array, 2 disk enclosures, 10 RAID 1 LUNs Hardware Configuration Host – FC60 controllers connected directly to host FC adapters – Two disk enclosures with ten 18 GB disk modules in each FC Adapter A FC Adapter B –...
  • Page 3 A5277AZ Factory Configuration for 3 Disk Enclosures Recommended FC60 HA Configuration Single host, dual-controller disk array, 3 disk enclosures, 15 RAID 1 LUNs Host Hardware Configuration FC Adapter A FC Adapter B – FC60 controllers connected directly to host FC adapters –...
  • Page 4 A5277AZ Factory Configuration for 4 Disk Enclosures Recommended FC60 HA Configuration Single host, dual-controller disk array, 4 disk enclosures, 10 RAID 0/1 LUNs Hardware Configuration Host – FC60 controllers connected directly to host FC adapters FC Adapter A FC Adapter B –...
  • Page 5 A5277AZ Factory Configuration for 5 Disk Enclosures Recommended FC60 HA Configuration Single host, dual-controller disk array, 5 disk enclosures, 10 RAID 0/1 & 5 RAID 1 LUNs Host FC Adapter A FC Adapter B Hardware Configuration FCAL-B FCAL-A – FC60 controllers connected directly to host FC adapters –...
  • Page 6 A5277AZ Factory Configuration for 6 Disk Enclosures Recommended FC60 HA Configuration Single host, dual-controller disk array, 6 disk enclosures, 10 RAID 0/1 LUNs Host FC Adapter A FC Adapter B FCAL-B FCAL-A Hardware Configuration – FC60 controllers connected directly to host FC adapters Controller A Controller B –...

This manual is also suitable for:

A5277az