Using QuickLoop
The looplet error recovery procedure includes the following steps:
1. LIPs are issued to the looplet, and it is determined whether the hidden
2. The rest of the standard Loop Initialization Sequences are completed, and it is
3. The looplet is kept idle and it is determined whether it remains stable.
If the procedure fails at any of the above steps, the looplet remains isolated from
the QuickLoop, and the procedure is executed again after the time-out period. If
all the steps are successfully completed, the looplet is reinstated into the
QuickLoop by full initialization.
24
FL_Port enters OPEN-INIT and becomes the Loop Initialization Master.
determined whether the looplet can be fully initialized within a time-out
period.