Download Print this page

Dell PowerEdge SE400 Manual page 7

Cluster systems

Advertisement

Ta b l e 1 - 3 .
P C I / P C I - X S l o t A s s i g n m e n t s f o r P o w e r E d g e C l u s t e r N o d e s ( c o n t i n u e d )
PowerEdge
PCI Buses
System
2500
PCI bus 1: PCI
slots 6 and 7 are
32-bit, 33 MHz.
PCI bus 2: PCI
slots 3, 4, and 5 are
64-bit, 33 MHz.
PCI bus 3: PCI
slots 1 and 2 are
64-bit, 66 MHz.
2550
PCI bus 1: PCI
slots 1, 2, and 3 are
64-bit, 33 MHz.
RAID Controller
Install in any available
PCI slot.
Install in any available
PCI slot.
If you are not using a
DRAC II, Dell
recommends that you
install one RAID
controller in the 32-bit
slot, even if the RAID
controller is a 64-bit
controller.
NICs
Install in any available PCI slot.
NOTE: The Broadcom NIC drivers in
your cluster node must be
Windows 2000 Advanced Server,
version 2.43 or later.
NOTE: The Broadcom NIC firmware
version must be 1.12 or later. The
integrated Broadcom NIC firmware
revisions were created in ascending
order, starting with version 1.1 and
ending with 1.12 or later.
Consequently, version 1.2 is an earlier
version than version 1.12. To upgrade
the firmware, at the prompt, type
upgf x boot y where x is the
device number of the integrated
Broadcom NIC and y is the drive
letter of where the firmware file is
located. The utility upgrades the
integrated NIC firmware in your
system. The driver and utility to
upgrade the firmware are available on
the Dell Support website at
support.dell.com.
Pl atf or m G uid e
DRAC II or III
Install the DRAC
II in PCI slot 7.
Install the DRAC
II in PCI slot 2.
1-5

Advertisement