Summary of Contents for Waterford LEPRECHAUN 90 O.S.A
Page 1
LEPRECHAUN 90 O.S.A WOODBURNING STOVE SAFETY NOTICE Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury or even death. This appliance is hot while in operation and retains its heat for a long period of time after use. Children, aged or infirm persons should be supervised at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled.
TOP FLUE EXIT LEPRECHAUN 90 O.S.A. WOODBURNING STOVE Fit part no. 14 over top Spacer INSTALLATION & OPERATING flue aperture in the hob INSTRUCTIONS (Part No. 13) make sure GENERAL that part no. 14 is well Heat Shield The complete installation must be done in accor- secured on a bed of fire dance with current Standards and Local Codes.
Rear Exit: FLOOR PROTECTION Fit the heat shield as follows: When installing this heater on a combustible floor, a floor protector, consisting of a layer of non-com- Screw the four 4” 100mm x 1/4” 6mm tie bolts to the bustible material at least 3/8” (9.5mm) thick or 1/4” back panel (item 11).
WARNING Air inlets traversing cavity walls should DO NOT OBSTRUCT FREE AIR SUPPLY TO THE include a continuous duct across the cavity. AIR INLET DUCT LOCATED AT THE BACK OF The duct should be installed in such a man THE STOVE. ner as not to impair the weather resistance of the cavity.
WALL PROTECTORS The chimney system shall comply with the standard for Chimney’s Factory-Built Residential Type and Building Heating Appliances UL 103. Any openings in a chimney guard if used must not permit the entrance of a 3/4” (19mm) diameter rod. CAUTION: THE STRUCTURAL INTEGRI TY OF THE MOBILE HOME ROOF, FLOOR, WALLS AND CEILING MUST BE...
Page 6
All clearances shall be measured from the Chimney, installed in accordance with the manufac- outer surface of the combustible material to turers instructions or a lined masonry chimney acceptable to the authority having jurisdiction. the nearest point on the surface of the Leprechaun 90 O.S.A., disregarding any intervening protection applied to the com- CHIMNEY CONNECTORS...
Page 7
U.S. ENVIRONMENTAL PROTECTION AGENCY LEPRECHAUN 90 O.S.A. Ashtray Certified to Comply with July 1990 WOOD BURNING STOVE Base Particulate Emission Standards Base Heat Shield Combustion Chamber Base Plate Maximum Heat Output up to 33,000 BTU’s/hr EXPLODED VIEW Fire Door Heat Output Range 9,000 - 26,700 BTU’s/hr Side Panels Inside Fire Door Door Latch...
Page 8
THIMBLES Solid insulated listed factory-built chimney length of the same inside diameter as the Thimbles for chimneys or vent connectors should be chimney connector and having 1” (25mm) or of fire clay (ASTM C 315, specifications for Clay more of insulation with a min. 9” (230mm) air Flue Linings), galvanised steel of minimum thick- space between the outer wall of the chimney ness of 24 gauge, or material of equivalent durabili-...
between the outer wall of chimney section other listed chimney connector from the appliances and shall be 12” (305mm). Chimney flue outlet up through the fireplace damper and section concentric with and spaced 1” smoke chamber, terminating at the first flue tile, or (25mm) away from connector by means of by installing a stainless steel or other listed relining sheet steel support plates on both ends of...
Existing fuel-fired equipment in the house, has caught fire adjust the primary air settings such as fireplaces or other heating appli- to suit the heat requirements. ances, smell, do not operate properly, suffer The logs will burn slowly towards the rear of smoke roll-out when opened, or back-draft the fire chamber and the rate of burning is whether or not there is combustion present.
MAINTENANCE When inspecting a masonry chimney, start at the cleanout door, normally found in the basement, at WARNING: DO NOT CLEAN STOVE WHEN HOT. the base of the chimney, or on the outside. If your chimney does not have a clean-out door it must be GLASS inspected and cleaned by removing stove from chimney.
WARNING: USE ONLY CERAMIC GLASS 5mm A practiced evacuation plan. THICK. ABUSE SUCH AS STRIKING, SLAMMING A plan to deal with a chimney fire as follows: SUBSTITUTE MAT E R I A L S SHOULD BE AVOIDED. IN THE EVENT OF A CHIMNEY FIRE FIRE SAFETY Notify the fire department.
Need help?
Do you have a question about the LEPRECHAUN 90 O.S.A and is the answer not in the manual?
Questions and answers