Installation - Regency Heatwave P36 Installation Manual

Heat wave duct kit
Table of Contents

Advertisement

INSTALLATION

NOTE: Installation of Heat Wave duct kit should
be done prior to drywall installation.
A) P36, P36D, P42, P48, P90, P95 & HZ54
models:
1) Remove the cover plate from the fi replace
side and discard.
Remove the 2 screws holding the cover plate
on the fi replace side.
2) Remove the knock-out and bend the tabs
outward.
Tab
Tab
Tab
Center Round
Duct collar over
hole and attach
to the tabs using
3 screws
NOTE: This must be done prior to placing
fi replace into fi nal position.
4
A) P90 / P95 Model:
1) Remove the knockout plate from the fi re-
place top and discard.
Knockout
plate
2) Bend the tabs outward.
Tab
Tab
Tab
3) Cut out and remove the insulation under the
top opening.
4) Push Round Duct Collar through to inner
shell top and attach to all 3 tabs on fi replace
top with screws.
Round Duct Collar
pushed down to
inner shell
B) All models:
1) Determine the location of the air register/fan
housing assembly. Cut a 5" x 16" (121mm
x 406mm) hole between framing members
(wall studs or fl oor joists). Maintain a 1/4"
(6mm) clearance from fan housing to com-
bustible material. See page 2 for clearances.
2) Mount and secure the fan housing assembly
to framing members, the front of the fan
housing will protrude 1/2" (51mm) out of
the wall so it may be fi nished with drywall,
etc. See diagram 2.
Front View
Tabs
Diagram 2 Side View: Secure fan housing
to minimum 2 x 4 framing.
Regency Heat Wave Air Duct Kit

Advertisement

Table of Contents
loading

This manual is also suitable for:

Heatwave p42Heatwave p36dHeatwave p48Heatwave p90Heatwave p95Heatwave l676s ... Show all

Table of Contents