Listings And Code Approvals; General Information - Regency Heatwave P36 Installation Manual

Heat wave duct kit
Table of Contents

Advertisement

LISTINGS AND CODE
APPROVALS
This Kit has been approved for use with Model
P36, P36D, P42, P48, P90, P95, L676S, P33S
& HZ54. This kit has been tested in accordance
with National Safety Standards, and has been
certifi ed by Warnock Hersey for installation and
operation in the United States and Canada as
described in these Installation and Operating
Instructions.
Check with your local building code agency
before you begin your installation to ensure
compliance with local codes, including the
need for "permits" and follow-up inspections. If
any problems are encountered regarding code
approvals, or if you wish clarifi cation on any of
the instructions contained here, contact your
local dealer.
Included with Kit:
1
946-010 20 ft. (6.1 m) of 6" dia. fl ex pipe
1
946-517 Fan housing assembly
1
910-423 Variable wall rheostat
1
946-006 Air register
1
946-005 Register adaptor frame (thick)
1
946-000 Round Duct collar
1
946-001 Oval Duct collar
1
946-002 Duct adaptor (round to oval)
1
946-045 Insulation (60")
Hardware package
If any parts are missing or damaged, contact
your dealer before starting installation. DO
NOT install a damaged kit.
2
GENERAL
INFORMATION
The Heat Wave Air Duct Kit increases the ef-
fectiveness of your fi replace by dispersing warm
air from the fi replace to remote locations in the
same room or other rooms in your home.
Up to two kits may be installed on the fi replace.
Please Note: Only 1 HeatWave kit may be
operated at one time. This includes the internal
blower option as well.
IMPORTANT
INSTALLATION NOTES
1) The appliance installation must conform with
local codes or, in the absence of local codes,
with the current Canadian or National Gas
Codes, CAN1-B149 or ANSI Z223.1 Instal-
lation Codes.
2) The appliance when installed, must be elec-
trically grounded in accordance with local
codes, or in the absence of local codes with
the current National Electrical Code, ANSI/
NFPA 70 or CSA C22.1 Canadian Electrical
Code.
PARTS
Diagram 1: Guide for possible air duct runs and locations. Keep duct length and number of
bends to a miniumum. Maximum duct length is 20 ft. (6.1m) per kit.
3) This kit is tested and safe when installed
in accordance with this installation manual.
Please read all instructions before starting
installation and follow all instructions care-
fully during installation.
4) Installation of this kit must be performed by
a qualifi ed service technician.
5) The Heat Wave Kit must be installed only
as specifi ed. Any modifi cations of the kit or
components will void the warranty and may
cause a fi re hazard.
6) Plan the location of the fi replace and the
warm air duct runs, see diagram 1 as a
guide for possible duct runs and locations.
Maximum Duct Run: 20 ft. (6.1m) per
kit.
NOTE: Airfl ow through the duct system is
affected by the duct length and number of
bends. Keep the length and bends to a
minimum to maximize performance.
Regency Heat Wave Air Duct Kit

Advertisement

Table of Contents
loading

This manual is also suitable for:

Heatwave p42Heatwave p36dHeatwave p48Heatwave p90Heatwave p95Heatwave l676s ... Show all

Table of Contents