LISTINGS AND CODE
APPROVALS
This Kit has been approved for use with the
following Gas Fireplace Models; City 40 Series,
City 72 Series, HZ54E, HZ33CE, HZ40E, P33,
P33CE, P33E, P36, P36E, P36D, P90 ,U900E
U1500E, G800EC and G800C. This kit has
been tested in accordance with National Safety
Standards, and has been certified by Warnock
Hersey/Intertek for installation and operation in
the United States and Canada as described in
these Installation and Operating Instructions.
Check with your local building code agency
before you begin your installation to ensure
compliance with local codes, including the
need for "permits" and follow-up inspections. If
any problems are encountered regarding code
approvals, or if you wish clarification on any of
the instructions contained here, contact your
local dealer.
Included with Kit:
1 946-597 20 ft. (6.1m) 6" dia. aluminum flex
pipe (946-753 only)
1
946-010 20 ft. (6.1 m) of 6" dia. flex pipe
(946-556 only)
1
946-517 Fan housing assembly
1
910-412 Variable wall rheostat
1
946-006 Air register
1
946-005 Register adaptor frame (thick)
1
946-000 Round Duct collar
1
946-001 Oval Duct collar
1
946-002 Duct adaptor (round to oval)
1
946-045 Insulation (60")
Hardware package
If any parts are missing or damaged, contact
your dealer before starting installation. DO
NOT install a damaged kit.
NOTE: For the City 40 Series, adaptor kit
#656-995 must be used with HeatWave kit
946-556.
For the City 60 Series, adaptor kit
#946-766 must be used with HeatWave kit
#946-753.
For the City 72 Series, adaptor kit is not required.
2
GENERAL
INFORMATION
The Heat Wave Air Duct Kit increases the ef-
fectiveness of your fireplace by dispersing warm
air from the fireplace to remote locations in the
same room or other rooms in your home.
Up to two kits may be installed on the fireplace.
Please Note: Only 1 HeatWave kit may be
operated at one time. This includes the internal
blower option as well.
IMPORTANT
INSTALLATION NOTES
1. The appliance installation must conform with
local codes or, in the absence of local codes,
with the current Canadian or National Gas
Codes, CAN1-B149 or ANSI Z223.1 Instal-
lation Codes.
2. The appliance when installed, must be elec-
trically grounded in accordance with local
codes, or in the absence of local codes with
the current National Electrical Code, ANSI/
NFPA 70 or CSA C22.1 Canadian Electrical
Code.
PARTS
Diagram 1: Guide for possible air duct runs and locations. Keep duct length and number of
bends to a minimum. Maximum duct length is 20 ft. (6.1m) per kit.
3) This kit is tested and safe when installed
in accordance with this installation manual.
Please read all instructions before starting
installation and follow all instructions care-
fully during installation.
4) Installation of this kit must be performed by
a qualified service technician.
5) The Heat Wave Kit must be installed only
as specified. Any modifications of the kit or
components will void the warranty and may
cause a fire hazard.
6) Plan the location of the fireplace and the
warm air duct runs, see diagram 1 as a
guide for possible duct runs and locations.
Maximum Duct Run: 20 ft. (6.1m) per
kit.
NOTE: Airflow through the duct system is
affected by the duct length and number of
bends. Keep the length and bends to a
minimum to maximize performance.
FPI Heat Wave Air Duct Kit